INSTALLATION

Electronic Controller Installation (Turn off power before making any electrical connections)

Connecting to an Electronic Controller

An Electronic Control System (Jandy® AquaLink RS (version I, K or L), Polaris® EOS, or Pentair IntelliTouch®) may be connected to the external RS-485 or the internal connector (marked TB1 on the lower Circuit Board) using a 4-wire cable (Jandy JDY-4278 or equivalent). Program “Select Remote” to match the Electronic Control System, see pg. 35.

Electronic Controller

 

External RS-485

Low Voltage

 

Terminal

Access Port

Electronic Controller

 

 

Terminal

 

 

TB1

 

 

#1#2 #3 #4

 

 

# 838 PCB

#75003 Digital Control Panel Base Plate

Electronic Controller Terminals on Circuit Board

Jandy® Controller:

Connect to the red

4-pin connector on the rear of the Jandy circuit board, matching the color code in the chart below. Connect in parallel to the existing wires.

Polaris® Controller:

Connect to the

4-pin removable connector on the command center board, matching the color code in the chart below.

Pentair Controller:

Connect to any of the IntelliTouch® COMM ports and match to the color code in the chart below.

On the Pool Pilot Digital:

 

Pool Pilot

 

Jandy

Polaris

Pentair

External RS-485

 

Internal Connection

 

 

 

# 1

 

# 1 (+ 9 V)

Red

Pin #4

Red

 

 

 

 

 

 

 

# 2

 

# 2

(+ DATA)

Black

Pin #1

Yellow

 

 

 

 

 

 

 

# 3

 

# 3

(- DATA)

Yellow

Pin #2

Green

 

 

 

 

 

 

 

# 4

 

# 4

(GND)

Green

Pin #3

Black

 

 

 

 

 

 

 

#4 #3 #2 #1

RS-485 wire harness

External RS-485 Terminal on Digital Base Plate

24