Optional Tap
Points
For
Digital TC
Total Control

INSTALLATION

pH Control Installation

Plumbing

Have these tools on hand prior to starting this step:

Drill

1/2” standard drill bit (or 1/4” NPT bit and tap if using Stenner components)

Utility knife

A hole must be drilled into the manifold assembly for installation of the injector fitting for the Muriatic Acid.

1.Locate the Acid Feed Pump and tank within proper cord

distances to the Pool Chemistry Controller System and Power source.

2.Turn the pump off, disconnect the cell and tri-sensor cords, and remove the manifold piping (without the cell) to a clean

Optional Tap Points

For

Digital TC

Total Control

Acid In

 

 

 

Tap Point

 

 

Locations

 

 

 

 

 

Water Out

 

Always Insert tubing into appropriate inlet/outlet.

See Digital TC manual for drilling instructions.

working area. See diagram for which unions to remove (marked in diagram above).

3.Locate the label on the manifold assembly marked “Optional Tap Points” (marked in diagram above), and drill the appropriate mounting hole adjacent to where indicated on the label marked “Acid In”. Do not drill through the label!

Use a drill stop attachment if available, or wrap a piece of masking tape, exposing 1” of the tip of the drill bit as a stop indicator. This will prevent drilling through the far side of the PVC, damaging the manifold.

Note: Use care to drill the hole perpendicular and deburr, for a leak-free connection of the injector fitting. Do not over drill or ream the hole as oversized holes will leak and are not covered under warranty.

Follow steps #4 and 5 if using AutoPilot factory components or skip to #6 if using Stenner factory

components

 

 

 

4. Insert the black injector fitting (Uniseal) into the ½” hole.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acid In

Note: Do not use any lubrication or sealing compounds!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tap Point

 

 

 

 

 

 

 

 

 

 

Locations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5. Insert the one-direction check valve assembly into the Uniseal, and then insert the AutoPilot supplied

 

Water

 

Out

black plastic tubing (marked 1/8” ID x ¼” OD) onto the check valve. Ensure the tubing is square

Always Insert tubing

into appropriate

inlet/outlet.

edged before inserting (use the utility knife to cut if needed).

See Digital TC

manual

 

 

 

Note: If it seems too tight, use some water or dishwashing detergent. Do not use any other lubricants!

 

 

 

6.IF USING THE STENNER FACTORY COMPONENTS, FOLLOW THE INSTRUCTIONS IN THE

 

STENNER INSTALLATION MANUAL AND USE ALL STENNER SUPPLIED TUBING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AND FITTINGS as AutoPilot and Stenner factory tubing and fittings are not

 

 

 

 

 

 

 

 

 

 

 

interchangeable.

 

 

 

 

 

 

 

 

 

 

 

7. If the acid collection tube has not already been installed, do so at this time.

 

Stenner

 

This will connect to the closer fitting on the Stenner head assembly.

 

 

Acid Pump

 

8. Roll out the tubing to connect into the Acid Feed Pump, again ensuring a squared edge.

 

and Tank

 

Leave enough slack in the tubing to secure the tubing with ty-wraps.

 

 

 

 

 

 

Kit

 

! Warning

 

Avoid any sharp bends and over tightening the Ty-Wrap to the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tubing, which can hinder proper flow of the chemicals

 

 

 

 

 

 

 

 

 

 

9.Remove the tank access lid and adjust the Stenner acid tank tubing weight so that it is about 1/2” (1.5 cm) from the bottom

of the tank.

10. Add 1 – 2 gallons of water into the acid tank.

STOP! At this point, turn on the circulation pump and perform the “Prime Acid Pump”, see pg. 35, and check for any leaks in the acid tubing and fittings.

11. Once secured and adjusted, continue adding water and muriatic acid into the tank for a recommended acid mixture of 4 parts water to 1 part muriatic acid dilution.

 

! Warning

 

To avoid damaging splashes, ALWAYS ADD

 

 

ACID TO WATER, never water to acid.

 

 

 

 

 

 

22