TropiCal: Table of Specifications

￿

MODELS:

 

T65”X”-A

T65”X”-B

T115 “X”-A

T115 “X”-B

T135 “X”-A

T135 “X”-B

 

BTU - 80%RH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air ºF / Air ºF…

80/50

55000/37000

55000/37000

104,000/70,000

104,000/70,000

126,000/82000

126,000/82000

 

 

 

 

 

 

 

 

COP

 

4.8/3.7

4.8/3.7

4.3/3.2

4.3/3.2

5.7/4.0

5.7/4.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BTU - 63% RH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air ºF / Air ºF…

80/50

51000/34000

51000/34000

97,000/65,000

97,000/65,000

119000/77000

119000/77000

 

 

 

 

 

 

 

 

COP

 

4.5/3.6

4.5/3.6

4/3.1

4/3.1

5.4/3.8

5.4/3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Kilowatt Input (80% RH)

3.4

3.4

7.1

7.1

6.5

6.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage/Hz/Phase

208-230/60/1

208-230/60/3

208-230/60/1

208-230/60/3

208-230/60/1

208-230/60/3

Min. Circuit Ampacity

20.01

14.04

40.56

26.14

37.36

30.14

Recommended Fuse Size

20

15.00

40

30

40

35

 

 

 

 

 

 

 

Max. Fuse or Breaker Size

30

20.00

70

40

60

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min-Max Water Flow (gpm)

20-70

20-70

20-70

20-70

20-70

20-70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping weight (lbs)

250

250

270

270

300

300

 

 

 

 

 

 

 

 

Shipping Size (l x w x h)

 

36" X 30" X 35"

36" X 30" X 35"

36" X 30" X 35"

36" X 30" X 35"

36"X30"X42

36"X30"X42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Uncrated Weight (lbs)

223

223

243

243

273

273

 

 

 

 

 

 

 

 

 

￿

￿

Refrigerant Circuit Performance Charts

Use of Charts- Information for the Technician:

The charts are intended for use by trained and qualified air-conditioning and refrigeration technicians only. The charts are compiled specifically for evaluation and diagnostic purposes, and are NOT designed for use as charging charts. To apply the chart data to actual conditions: gather the operating pressures, suction tube superheat & liquid line subcooling values, water temperature change through the heater, and the total unit amps. Locate a chart that most closely represents current actual conditions. Readings obtained that differ from the charts in excess of 10% (+ or -), may indicate a problem within the mechanical refrigeration system. Reference: Troubleshooting Refrigerant Circuit Problems, following the charts. Some interpolation between charts will be necessary should actual conditions not align reasonably well with the charts. Should refrigerant circuit readings appear normal, but not the Water DT value, the likely cause will be water flow above or below 45 GPM. (TropiCal refrigerant circuits will perform acceptably with condenser water flow between 20 to 70 GPM.)

Performance Charts Follow