Troubleshooting Flow Charts

Heater Fails to Operate

Analog Controls - 12/22/03

START

Is the thermostat turned UP,

 

 

and the toggle or rocker switch

 

 

Yes

 

 

No

 

 

 

 

selecting either the

 

 

 

 

 

 

 

 

SPA or POOL

 

 

 

 

thermostat ?

 

 

Check to be sure the power light is on. If the power light is off, check for a tripped circuit breaker. Reset the circuit breaker if necessary.

Yes

Is the heater

operating correctly?

 

Position controls to

select POOL or SPA;

rotate selected

thermostat to the maximum setting.

No

Check to see that the pool pump is operating and the flow light is on.

Make sure all water

valves are in the correct

position and the filter and pump basket are clean.

 

 

Is the heater

 

 

Yes

 

No

 

operating correctly?

 

 

 

 

 

The heater is equipped with a five minute delay.

Wait at least five

minutes to allow the

timer to reset.

Problem

Solved.

(Re-set thermastats

to desired

temperature)

Yes

Is the unit operating

correctly?

 

 

No

Contact

AquaCal for

Assistance at: 800-786-7751

30

Page 30
Image 30