AquaStar 38B LP, 38B NG specifications Open loop potable water and combination space heating system

Models: 38B LP 38B NG

1 16
Download 16 pages 47 Kb
Page 3
Image 3
Open loop potable water and combination space heating system*

If you are using the AquaStar for combined space heating and potable water heating (see schematic diagram below), all piping and other components connected to the system must be suitable for potable water, (b) toxic chemicals such as those commonly used for boiler treatment to prevent corrosion and freezing must not be introduced into the system, and

(c)if the space heating requires water temperatures higher than those required for do- mestic, potable water, a mixing valve or other similar device must be provided to reduce scald hazard potential, (d) maximum system water temperature must not exceed 140°F

(60°C). DO NOT CONVERT AN EXISTING, CLOSED HOT WATER HEATING SYSTEM TO A COMBINATION SPACE AND POTABLE WATER HEATING SYSTEM USING THE AQUASTAR OR ANY OTHER HEAT SOURCE.

Open loop potable water and combination space heating system*

* To be used with a tank, check local codes. May not be permitted in some jurisdictions.

 

 

Notes

 

1.

Maximum operating temperature of 38B: 140°F

 

 

2.

Maximum heating capacity:

40°F rise

20°F rise

 

AquaStar 38B -

30,000 BTU/hr

15,000 BTU/hr

3.System shown is electric storage tank with recirculating supply drawn from the tapping for the lower heating element.

4.Schematic is for illustration and example only and must not be used for actual installation without appropriate engineering and technical advice from a professional properly licensed in the locality where the installation is made.

3