AquaStar 38B NG Water Pressure, Installation Checklist, Gas Line Size, Nominal Iron Pipe Size

Models: 38B LP 38B NG

1 16
Download 16 pages 47 Kb
Page 16
Image 16
INSTALLATION CHECKLIST

INSTALLATION CHECKLIST

 

GAS LINE SIZE

 

 

 

Natural Gas

 

 

 

 

 

 

 

Nominal Iron Pipe Size*

 

3/8"

1/2"

 

 

 

 

 

 

MAXIMUM LENGTH

 

20'

80'

 

 

 

 

 

 

 

Liquid Propane

 

 

 

 

 

 

 

Semi-rigid Tubing

 

3/8"

1/2"

 

 

 

 

 

 

MAXIMUM LENGTH

 

10'

60'

 

 

 

 

 

 

* Flex tubing greatly reduces capacity and, therefore, is not recommended.

Minimum Vent Size* and Height

Minimum Diameter

Minimum Height**

 

 

4 inches

6 feet**

 

 

*NOTE: Vent size must not be restricted. Installation must comply with national fuel gas code venting requirements for a 40,000 Btu Category I appliance and any applicable local codes.

**NOTE: 6 feet, provided there are no elbows. Termination of vent must be 2 feet above any obstruction within a

10 foot radius. Consult your gas utility or National Fuel Gas Code if vent will have elbows or share venting with another appliance. The vent connector should have as much vertical rise as possible (minimum 12") before any horizontal run.

Water Pressure

For installation on well systems, insure that your water pressure is between 30 - 50 psi.

Replacement Parts available from North American Distributor

CONTROLLED ENERGY CORP.

340 Mad River Park

Vermont 05673 (U.S.A.)

Phone 800-642-3111

Fax (802) 496-6924

VULCANO Termodomésticos S.A.

Estrada de Cacia

3800 Cacia - PORTUGAL

WWW.CECHOT.COM techsupport@cechot.com