INSTALLATION CHECKLIST
| GAS LINE SIZE |
|
| |
| Natural Gas |
|
| |
|
|
|
|
|
Nominal Iron Pipe Size* |
| 3/8" | 1/2" |
|
|
|
|
|
|
MAXIMUM LENGTH |
| 20' | 80' |
|
|
|
|
|
|
| Liquid Propane |
|
| |
|
|
|
|
|
|
| 3/8" | 1/2" |
|
|
|
|
|
|
MAXIMUM LENGTH |
| 10' | 60' |
|
|
|
|
|
|
* Flex tubing greatly reduces capacity and, therefore, is not recommended.
Minimum Vent Size* and Height
Minimum Diameter | Minimum Height** |
|
|
4 inches | 6 feet** |
|
|
*NOTE: Vent size must not be restricted. Installation must comply with national fuel gas code venting requirements for a 40,000 Btu Category I appliance and any applicable local codes.
**NOTE: 6 feet, provided there are no elbows. Termination of vent must be 2 feet above any obstruction within a
10 foot radius. Consult your gas utility or National Fuel Gas Code if vent will have elbows or share venting with another appliance. The vent connector should have as much vertical rise as possible (minimum 12") before any horizontal run.
Water Pressure
For installation on well systems, insure that your water pressure is between 30 - 50 psi.