Unsealed; Single Pipe System
Exhaust Venting:
This heater requires Category III
Single Pipe
Horizontal
Intake/Combustion Air:
Ambient (room) air can be used provided it meets the combustion air requirements as specified by the National Fuel Gas Code. See AquaStar 250SX Installation Manual for details.
The exhaust vent pipe has a maxi- mum length of 26 feet (8m) with one elbow. For each additional elbow after the first elbow, you must reduce 2.5 feet from the total length. A maximum of 3 elbows is allowed.
A condensate drain kit must be used in all installations.
A condensate drain kit is included with the AquaStar 250SX.
Additional Venting Items
7.36
5.38
2SVEEWCF0345
45 Degree Elbow 3"
11.50
2SVEPWCF0301
Pipe 3" x 12"
Hose Clamp
Condensate tube/trap
A condensate drain kit must be used in all installations.
Hose Clamp | A condensate drain |
kit is included with | |
| every AquaStar |
| 250SX. |
24" Tube | Cable Tie |
2SVEDTK24
Condensate Drain Kit
Items not drawn to scale.
Not all additional venting items shown. See back page for complete list.