Installation

Installation

Grounding and Electric

Requirements

WARNING

Your system must be grounded. Read warnings, page 3.

The sprayer cord includes: a grounding wire with an appropriate grounding contact.

The sprayer requires:

110-120V Units: 100-130VAC, 50/60 Hz, 11A, 1 phase, circuit with a grounding receptacle.

240V Units: 210-255 VAC, 50/60 Hz, 7.5A, 1 phase, cir- cuit with a grounding receptacle.

Never use an outlet that is not grounded or an adapter.

Do not use the sprayer if the electrical cord has a dam- aged ground contact. Only use an extension cord with an undamaged ground contact.

Recommended extension cords for use with this sprayer:

110-120V: 3-wire, 12 AWG (2.5 mm2) minimum, 300 ft. (90 m) maximum length.

240V: 3-wire, 16 AWG (1.0 mm2) minimum, 300 ft (90 m) maximum length.

Smaller gauge or longer extension cords may reduce sprayer performance.

Spray gun: ground through connection to a properly grounded fluid hose and pump.

Fluid supply container: follow local code.

Solvent and Oil-based fluids: follow local code. Use only conductive metal pails placed on a grounded sur- face such as concrete. Do not place the pail on a non- conductive surface such as paper or cardboard, which interrupts grounding continuity.

Grounding the metal pail: connect a ground wire to the pail by clamping one end to pail and other end to ground such as a water pipe.

To maintain grounding continuity when flushing or relieving pressure: hold metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.