Manifold Replacement
See Wiring Diagram, page 28.
WARNING
Read Electric Shock Warning, page 3 and Pressure Relief Procedure, page 8.
Removal
1.Relieve pressure, page 8. Disconnect power cord from outlet.
2.Remove drain line (40) and barbed fitting (20) from manifold. See Drain Line Replacement, page 25.
3.Remove two screws (30) and shroud (29).
4.Disconnect fluid hose at pump outlet.
5.Disconnect pressure switch connector (A) from con- trol board (33).
6.Remove tape (22) holding wires to manifold.
7.Pull wires back through hole (K) in housing.
8.If required, remove pressure switch from manifold. See Pressure Control Assembly Replacement, page 23.
9.Remove two screws (6) to disconnect Manifold from housing.
Installation
1.Position manifold on sprayer frame.
2.Replace screws (6) and torque to 150
3.If removed, install pressure control assembly. See Pressure Control Assembly Replacement, page 23.
4.Feed pressure switch wires through hole in housing
(K).
5.Insert grommet (21) in hole (K) in housing. Secure wires to manifold housing with tape (22).
6.Reconnect pressure switch connector (A) to control board (33).
Manifold Replacement
7.Reconnect fluid hose at pump outlet.
8.Replace barbed fitting (20) and drain line (40). See Drain Line Replacement, page 25.
9.Install shroud (29) and two screws (30).
|
|
| A |
| 18 | 33 | |
|
| ||
|
|
| A |
|
|
| 17 |
|
|
| 15 |
Ref 14 |
|
| 13 |
|
| C | |
|
|
| |
| 23 | 6 | 20 |
|
| ||
| 24 |
| B |
| 25 |
| |
26 |
| 40 | |
|
|
| |
|
|
| ti5771a |
A
33
18A
17
ProStep
13
Ref 14
6
20
23
24 40 25
26ti12077a
24 | 310824D |