Graco Inc ti5735a, 309639, 309250, 310820, 310876, 310824D Cord. See page 7, Grounding and Electric

Models: ti5638a ti5769a ti5642a ti6104a ti5641a 310824D 256391 310876 ti6122a ti6119a ti5735a 256481 ti5766a 309250 309639 ti11608a ti5643a ti9134b 310820 ti6125a ti5771a ti6105a ti6121a ti6106a ti5857a ti5637a ti6124a ti12008a ti12077a ti5639a ti6107a

1 30
Download 30 pages 16.3 Kb
Page 12
Image 12

 

 

 

Troubleshooting

 

 

 

 

Problem

 

What To Check

What To Do

(If check is OK, go to next check)

(When check is not OK, refer to this column)

 

 

 

 

 

 

 

 

Low Output

1.

Worn spray tip.

Relieve pressure, page 8. Replace tip. Refer to

 

 

 

gun instruction manual, 309639.

 

 

 

 

 

2.

Verify pump does not continue to

Service pump. See page 14, Displacement

 

 

stroke when gun trigger is

Pump Replacement.

 

 

released.

 

 

 

 

 

 

3.

Prime valve leaking.

Relieve pressure, page 8. Then repair prime

 

 

 

valve. See page 24, Manifold Replacement.

 

 

 

 

 

4.

Suction hose connections.

Tighten any loose connections. Check o-rings

 

 

 

on suction hose swivel.

 

 

 

 

 

5.

Electric supply with volt meter.

Reset building circuit breaker; replace building

 

 

Meter must read 100-130 VAC for

fuse. Repair electrical outlet or try another

 

 

110-120 VAC models and

outlet.

 

 

210-255 for 240 VAC models.

 

 

 

Low voltages reduce sprayer per-

 

 

 

formance.

 

 

 

 

 

 

6.

Extension cord size and length.

7. Replace with a correct, grounded extension

 

 

 

cord. See page 7, Grounding and Electric

 

 

 

Requirements.

 

 

 

 

 

8.

Leads from motor to circuit board

Be sure male terminal pins are centered and

 

 

for damaged or loose wire con-

firmly connected to female terminals. Replace

 

 

nectors. Inspect wiring insulation

any loose terminals or damaged wiring.

 

 

and terminals for signs of over-

Securely reconnect terminals.

 

 

heating.

 

 

 

 

 

 

9.

Worn motor brushes which must

Replace brushes. See page 19. Motor Brush

 

 

be 1/4 in. (6 mm) minimum.

Replacement.

 

 

 

 

 

10.

Motor brushes binding in brush

Clean brush holders. Remove carbon dust by

 

 

holders.

using compressed air to blow out brush dust.

 

 

 

 

 

11.

Low stall pressure. Turn pressure

Replace pressure control assembly. See page

 

 

control knob fully clockwise.

 

 

23, Pressure Control Assembly Replace-

 

 

 

 

 

 

ment.

 

 

 

 

 

12.

Motor armature for shorts by

Replace motor. See page 27, Motor

 

 

using an armature tester

Replacement.

 

 

(growler) or perform spin test,

 

 

 

page 17.

 

 

 

 

 

12

310824D

Page 12
Image 12
Graco Inc ti5735a, 309639, 309250, 310820, 310876, 310824D, 256481, 256391, ti9134b Cord. See page 7, Grounding and Electric