H200 Twin/Triplex/Fourplex Installation Top-Mount - First-in, Last-Out Piping Arrangement.

"MAV" Shown for demand recall. Four Plex shown for reference only.

Bypass Valve

 

Outlet

Shut-Off Valve

Isolation Valves

Shut-Off Valve

Inlet

 

 

 

Brine Tank(s)

 

Brine Tank(s)

 

 

 

Flex Connectors

MAV Valve

 

 

See NOTE Figure 5

 

Figure 4

MAV = Motorized Alternating Valve.

 

 

H200 Single Installation - Side Mount

Bypass Valve

Sidemount

Adapter Base

2” FNPT Inlet &

Inlet

 

2.5” Victaulic

 

 

Shut-Off Valve

Brine Line

 

Brine Tank

1" MNPT

 

 

 

2” FNPT Outlet &

Internal Meter

 

 

 

2.5” Victaulic

 

Outlet

Isolation

Valves

Figure 5

NOTE:

System connections to the tank must accommodate longitudinal movement between side, top and bot- tom openings, flexibility in piping or flex connectors are recommended.

Red colored piping, fittings, and connectors are for reference only and are not included. Must be fur- nished by others.

Union type connectors are recommended on the inlet and outlet connections.

1" Brine Line must be hard-piped, secured and supported for proper operation. CPVC or Schedule 80 PVC recommended.

MAV = Motorized Alternating Valve.

9

Page 9
Image 9
Argosy Research H200 Series, H200HF Series manual H200 Single Installation Side Mount