4
INSTALL THE DUCTWORK
(DUCTED HOODS ONLY)
Caution: To reduce the risk of fire, use metal
ductwork is preferred.
1. Decide where the ductwork will run between
the hood and the outside.
2. A straight, short duct run will allow the hood to
perform most efficiently.
3. Long duct runs, elbows, and transitions will
reduce the performance of the hood. Use as few of them as possible. Larger
ducting may be required for best performance with longer duct runs.
4. The air must not be discharge into a flue that is used for exhausting fumes from
appliances burning gas or other fuels" "Regulations concerning the discharge of air
have to be fulfilled.
5. Install wall cap. Connect round metal ductwork to cap and work back towards hood location. Use duct tape to seal the joints between ductwork sections.
INSTALL ELECTRICAL
Electrical wiring must be done by a qualified person(s) in accordance with all applicable
codes and standards. This range hood must be properly grounded. Turn off electrical
power at service entrance before wiring.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
INSTALL THE HOOD
Note 1 : On stainless steel hoods, carefully remove the plastic protective film from all
exterior surfaces of the hood and chimney prior to final installation.
Note 2: At least two people will be required to mount the hood.