Gas Connection to Flexible Steel Pipe

The gas feed connector to the appliance is a threaded, male 1/ 2" connector for round gas pipe. Only use pipes, tubes and gaskets that comply with current safety codes. The maximum length of the flexible pipes must not exceed 2000 mm.Once the connection has been made, ensure that the flexible metal tube does not touch any moving parts and is not crushed.

Check the Seal

Once the appliance has been installed, make sure all the connections are properly sealed, using a soapy water solution. Never use a flame.

Electrical Connection

The cooktops fitted with a tripolar electrical supply cord are designed to be be used with alternating current according to the indications on the rating plate located under the cooktop. The earthing wire can be identified by its yellow-green colour.

In the case of installation over a built-in electric oven, the electrical connections for the cooktop and oven should be independent, not only for safety purposes, but also to facilitate removal of one or both in the future.

Electrical Connection for Gas Cooktop

Fit the supply cord with a standard plug for the demand rate indicated on the rating plate or connect it directly to the electrical mains. In the latter case, a single pole switch must be placed between the appliance and the mains, with a minimum opening between the contacts of 3 mm in compliance with current safety codes (the earthing wire must not be interrupted by the switch). The power supply cord must be positioned so that it does not reach a temperature in excess of 50°C above room temperatu- re at any point.

Before making the actual connection, make sure that:

The fuse and electrical system can withstand the load required by the appliance;

That the electrical supply system is equiped with an efficient earth hook-up according to the norms and regulations prescribed by law;

That the plug or switch is easily accessible.

Important: the wires in the mains lead are coloured in accordance with the following code:

Green &Yellow

- Earth

Blue

- Neutral

Brown

- Live

As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

Connect the Green &Yellow wire to the terminal marked “E” or

or coloured Green or Green &Yellow.

Connect the Brown wire to the terminal marked “L” or coloured Red.

Connect the Blue wire to the terminal marked “N” or coloured Black.

Adapting the Cooktop for DifferentTypes of Gas

To adapt the cooktop to a different type of gas than that for which it was designed, (see the sticker under the hob or on the packaging), the burner nozzles must be changed, as follows:

Remove the pan supports and slide the burners out of the cooktop.

Unscrew the nozzles using a 7mm socket wrench and

replace them with those for the new type of gas.(See table 1, “Burner and Nozzle Specifications”).

Reassemble the parts following the instructions in reverse order.

On completing the operation, replace the old rating label with

the one showing the new type of gas; the sticker is available from our Service Centres.

If the gas pressure is different than that prescribed, a pressure regulator must be installed at the source, in compliance with national standards governing the use of piped gas regulators.

Replacing the nozzles on separate “double flame “ burners:

remove the grids and slide the burners from their housings. The burner consists of 2 separate parts (Fig. C and fig. D);

unscrew the burers with a 7 mm wrench spanner. The internal burner has a nozzle, the external burner has two (of the same size). Replace the nozzle with models suited to the new type of gas (see table 1).

replace all the components by repeating the steps in reverse order.

Fig. C

Fig. D

Regulation of Air Supply to the Burner

The burners do not need a primary air regulator.

Minimum Regulation

Turn the gas valve to minimum.

Remove the knob and turn the regulator screw (positioned either on the side of the top or inside the shaft) clockwise until the flame becomes small but regular.

N.B.: In the case of liquid gas, the regulation screw must be fully screwed in (clockwise).

Make sure that, when the knob is turned rapidly high to low, the flame does not go out.

In the event of a malfunction on appliances with the security

device (thermocouple) when the gas supply is set at minimum, increase the minimum supply levels using the regulator screw.

Once the adjustment has been made, apply sealing wax, or a suitable substitute, to the old seals on the by-pass.

18

Page 8
Image 8
Ariston PF750AST manual Gas Connection to Flexible Steel Pipe, Check the Seal, Electrical Connection, Earth, Live

PF750AST specifications

The Ariston PF750AST is a remarkable addition to the realm of advanced heating systems, designed to provide both efficiency and reliability for a range of residential and commercial applications. This innovative product stands out due to its robust construction, modern technologies, and user-friendly features, making it a popular choice among homeowners and professionals alike.

One of the standout characteristics of the PF750AST is its cutting-edge energy efficiency. It incorporates advanced heat exchange technology that maximizes thermal transfer while minimizing energy loss. This results in lower energy consumption, which not only helps the environment but also reduces utility bills for users. With an impressive energy efficiency rating, the Ariston PF750AST is an eco-friendly choice that meets strict international standards.

In terms of design, the PF750AST boasts a sleek and compact profile, making it easy to integrate into various installations. Its modern aesthetic ensures that it can blend seamlessly with different environments, from stylish urban apartments to traditional homes. The unit is engineered with durable materials that offer both longevity and resilience, ensuring sustained performance even in challenging conditions.

The PF750AST is equipped with smart technologies that enhance user experience. The integrated control panel allows for effortless temperature adjustments and operational monitoring, providing users with full command over their heating environment. Additionally, the system supports advanced connectivity features, enabling remote control via smartphones and smart home systems. This ensures users can maintain optimal comfort from anywhere in their homes.

Safety is of paramount importance with the Ariston PF750AST. It includes multiple safety features, such as an automatic shut-off mechanism and built-in overheat protection, ensuring a safe operation at all times. These features are essential for peace of mind, especially in households with children or pets.

Moreover, the PF750AST is designed for easy maintenance. The user-friendly construction allows for straightforward access to essential components, facilitating routine inspection and servicing. This not only extends the lifespan of the unit but also ensures that it operates at peak efficiency over time.

In summary, the Ariston PF750AST is a top-tier heating solution that combines efficiency, modern design, and advanced technology. With its impressive energy ratings, smart connectivity, and robust safety features, it meets the demands of both contemporary living and environmental considerations. Whether for heating a small room or an entire building, the PF750AST stands out as a reliable and effective choice.