Easy Installation in Existing Walls

TV Bridgein the upper box Make low voltage connections.

Easy Installation in Existing Walls

Components are not energized until the flexible cord is plugged in. Do not plug in until all other wiring is complete.

1Locate wall studs to position TV Bridge™ between studs.

2Position the upper box behind (or close to) the installed TV bracket. Position lower box within 3-1/2 ft. of the existing receptacle or power conditioner that will power the installation. Install upper box and lower box in the same stud cavity.

3Pull a length of NM cable long enough to reach both boxes. Pull low voltage, coaxial, speaker wires, etc. before installing the boxes.

4Install NM cable through the installed cable connector.

Attach the boxes securely to the wall by tightening the two wing screws.

5Wire the duplex receptacle and install it in the upper box.

6Install LPCG50W cord grip onto the flexible cord, then install

into the KD4550 using supplied locknut.

7Connect the cord conductors to corresponding conductors of NM cable installed in the lower box. Install wire nuts.

8Install KD4550 assembly to the lower box. Mount the CED13 cable entry device or CED1 entrance hood to the low voltage sides of both boxes (machine screws supplied).

9Install cover plates.

10Connect TV power cable to the installed duplex outlet

in the upper box Make low voltage connections.

C

 

Flat

screen

TV

CED1

Wires stay

hidden behind

wall

No messy

wires running down the wall

KD4550

LPCG50W

Flexible

cordCED13

CATALOG

UPC/DCI/NAED

DESCRIPTION

UNIT/STD

NUMBER

MFG #01 8997

 

PKG

TVBR2505K

09658

TV Bridge™

1

TVBR2505KGC 09108

TV Bridge™

1

 

 

with ground clip

 

 

 

(for Canada)

 

 

 

 

 

©2010 Arlington Industries, Inc.

Arlington

1 Stauffer Industrial Park Scranton, PA 18517

800/233.4717 Fax 570/562.0646

www.aifittings.com

www.arlnew.com

www.arlingtonlowvoltage.com

Note:

-This product is not designed to be an extension of a structure’s hard wiring.

-Components are not energized until the flexible cord is plugged in. Do not plug in until all other wiring is complete.

Patents pending

TVBR2505K 0410/15M

Includes (2) recessed boxes with trim plates and installed NM cable connectors, (2) duplex covers, wire nuts, tamper-resistant duplex receptacle, installation screws, LPCG50W cord grip,

4 ft. cord, KD4550 and The SCOOP™ (2) CED1 entrance hoods, (2) CED13 cable entry devices.

Distributed by
Page 2
Image 2
Arlington TVBR2505K Easy Installation in Existing Walls, TV Bridge, Arlington, Wires stay hidden behind wall No messy