TV Bridge™
Easy Installation in Existing Walls
Components are not energized until the flexible cord is plugged in. Do not plug in until all other wiring is complete.
1Locate wall studs to position TV Bridge™ between studs.
2Position the upper box behind (or close to) the installed TV bracket. Position lower box within
3Pull a length of NM cable long enough to reach both boxes. Pull low voltage, coaxial, speaker wires, etc. before installing the boxes.
4Install NM cable through the installed cable connector.
Attach the boxes securely to the wall by tightening the two wing screws.
5Wire the duplex receptacle and install it in the upper box.
6Install LPCG50W cord grip onto the flexible cord, then install
into the KD4550 using supplied locknut.
7Connect the cord conductors to corresponding conductors of NM cable installed in the lower box. Install wire nuts.
8Install KD4550 assembly to the lower box. Mount the CED13 cable entry device or CED1 entrance hood to the low voltage sides of both boxes (machine screws supplied).
9Install cover plates.
10Connect TV power cable to the installed duplex outlet
in the upper box Make low voltage connections. | C |
|
Flat
screen
TV
CED1
Wires stay
hidden behind
wall
No messy
wires running down the wall
KD4550
LPCG50W
Flexible
cordCED13
CATALOG | UPC/DCI/NAED | DESCRIPTION | UNIT/STD |
NUMBER | MFG #01 8997 |
| PKG |
TVBR2505K | 09658 | TV Bridge™ | 1 |
TVBR2505KGC 09108 | TV Bridge™ | 1 | |
|
| with ground clip |
|
|
| (for Canada) |
|
|
|
|
|
©2010 Arlington Industries, Inc.
Arlington
1 Stauffer Industrial Park Scranton, PA 18517
800/233.4717 Fax 570/562.0646
www.aifittings.com
www.arlnew.com
www.arlingtonlowvoltage.com
Note:
-This product is not designed to be an extension of a structure’s hard wiring.
-Components are not energized until the flexible cord is plugged in. Do not plug in until all other wiring is complete.
Patents pending
TVBR2505K 0410/15M
Includes (2) recessed boxes with trim plates and installed NM cable connectors, (2) duplex covers, wire nuts,
4 ft. cord, KD4550 and The SCOOP™ (2) CED1 entrance hoods, (2) CED13 cable entry devices.
Distributed by