Protect 6.FRONT PANEL INDICATORS6.2Signal Indicator6.3Clipping Indicator6.4Thermal Status Indicator6.5Protect IndicatorManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Thermal Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Clip

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

Signal Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Powerflex 6250

6.FRONT PANEL INDICATORS

6.1Power Switch

When the unit is switched on there is a five sec- ond delay, during which time the PROTECT circuit will activate, disconnecting the speakers from the amplifier output. When turning off the amplifier, the load is removed instantly, and the protect LED will briefly turn on as the power supply discharges.

6.2Signal Indicator

The signal present LEDs illuminate at an input level of about 13mVrms (-35.5dBu).

6.3Clipping Indicator

The clipping LEDs illuminate at an input level of about 870mVrms (+1.0dBu), with all channels driven by 1KHz into 8. This indicates that the signal processing circuitry has determined output levels to be approaching the available power supply rails and has begun to “soften” signal peaks. Actual onset of “hard” clipping depends on audio program and total load impedance and does not oc- cur until the signal processing circuitry can no longer com- pensate, which means that signal integrity can be maintained even if the clipping indicators illuminate for short periods of time.

6.4Thermal Status Indicator

The thermal LEDs illuminate when the tempera- ture of any one of the heat sink extrusions reaches 85 to 90°C. Both channels of the affected amplifier module will shut off until the measured temperature drops below about 70°C. The amplifier should be able to maintain proper

operation at an ambient room temperature of 50°C (122°F) or less with typical audio program and all channels driven into 4.

6.5Protect Indicator

The protect LEDs illuminate when the fault moni- toring microprocessor has determined that one of the fol- lowing conditions exists:

-Power supply undervoltage

-Power supply overvoltage

-Output overcurrent

-Heat sink overtemperature

-Unacceptable DC output content

-Unacceptable high frequency output content

-AC power interruption

Because the signal processing module used in Powerflex amplifiers processes two channels simulta- neously, a fault in one channel will result in a protect con- dition for both channels processed by the same module, ex. channels 1-2, 3-4, and 5-6 (6250 only). Thus there will never be a case where only one of the amplifier chan- nels is shown in protect mode. When a pair of protect LED's are illuminated, internal relays have removed the channel pair's speaker loads from the amplifier output and connected the speakers to ground. If the fault is isolated to one module (channel pair), the other channels will re- main unaffected.