Printer-related Symptoms

Symptom/Error

Action/FRU

 

 

 

Printing failed.

Ensure the printer driver is properly installed. Refer to the

 

 

printer service manual.

 

Printer

 

Printer cable

 

Mainboard.

 

 

 

Printer problems.

Refer to the service manual for the printer.

 

 

 

Keyboard-related Symptoms

 

 

 

 

Symptom/Error

Action/FRU

 

 

 

Some or all keys on keyboard do not work.

Keyboard

 

 

 

Power Supply-related Symptoms

 

 

 

 

Symptom/Error

Action/FRU

 

 

 

Pressing the power button does not turn off

Ensure the Soft-off by PWR-BTTN in CMOS Setup (under

the system. (Only unplugging the power

 

Power Management) is not set to Instant-off.

cord from electrical outlet can turn off the

• Power switch cable assembly

system.)

 

 

 

 

 

Pressing the power button does not turn on

Ensure the power override switch (located at the back of the

the system

 

computer, just above the connector for the power cable) is not

 

 

set to OFF.

 

• Power switch cable assembly.

 

 

 

Executing software shutdown from

Enter CMOS Setup and load the default settings.

Windows98 Start menu does not turn off the

Reload software from Recovery CD.

system. (Only pressing power button can

 

 

turn off the system).

 

 

 

 

 

No system power, or power supply fan is

Power supply

not running.

Mainboard

 

 

 

 

Aspire AX1400 Service Guide

59

Page 67
Image 67