Rev. A.1, 10/99

Page- 21

used. An "S" Senstat Magnalock, Touch Sense Bar and MK keyswitch are employed in place of the generic fail safe lock, initiate device and reset device.

FIG. 10: LCP/XDT CONNECTION USING SECURITRON MAGNALOCK, TOUCH SENSE

BAR, AND MK KEYSWITCH WITHOUT USE OF BYPASS FUNCTION

FROM POWER SUPPLY

 

 

 

LOCAL RELEASE SWITCH

 

IF A LOCAL RELEASE SWITCH IS NOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LCP "L" TERMINAL

COM

NC

 

 

 

 

 

 

USED, LCP "L" CONNECTS DIRECTLY

 

 

 

 

 

 

TO "C3" AND TO TSB WHITE WIRE;

LCP "E" TERMINAL

 

 

NO

 

 

 

 

 

 

LCP "E" CONNECTS TO "FE".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

GRN RED

 

 

 

 

 

 

 

WHT

 

 

 

LCP "S" TERMINAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHT MK KEY-

 

RS

 

 

 

 

 

 

 

 

RED

 

 

 

 

NC

 

 

SWITCH

IN

 

TSB GRN

 

C3

WHITE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

"S" SENSTAT

 

 

 

 

 

FE

 

 

BLK

 

RED

NO

MAGNALOCK

 

 

 

 

 

 

 

 

 

 

 

 

 

BP

 

 

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LS

 

 

 

 

 

 

C2

 

0V (NEG)

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

+V

 

 

+

 

 

 

 

 

 

 

 

 

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C1

+ SON-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

XDT BOARD

 

ALERT

 

 

 

 

 

 

 

 

 

LCP "Y" TERMINAL

Figure 11 shows general wiring when the bypass input is used. This is typically because either the LCP is using momentary switches or the local release switch is momentary. The bypass input will release the lock without signalling any alarm for 5 seconds. Use of the bypass input makes substantial changes in the entire wiring scheme. The lock status or door status switch no longer reports directly to the panel but rather reports to the XDT board lock status input. The reason for this is to avoid causing the panel to alarm when bypass is used for legal release. The XDT's lock status monitoring function will continue to report secure to the panel when any board function has released the lock and for 5 seconds after it has resecured the lock. This delay permits a door to complete closing and allows the lock time to "pull in" before an alarm condition is created.

One particular note is that if you employ the KP1 or MK1 switch bypass option, you will not bypass the toggles. Use of the toggle will still send power out of the E terminal and from there to the BP terminal on the XDT board which will release the lock. Do not use this option with delayed exit.

Page 23
Image 23
Assa ELECTRIC LOCK manual LED WHT MK KEY RED Switch

ELECTRIC LOCK specifications

Assa Electric Lock is a cutting-edge security solution designed to address the evolving needs of modern access control systems. Utilizing advanced technologies, this lock integrates both traditional locking mechanisms with state-of-the-art electronic features, providing an unparalleled level of security for residential and commercial properties.

One of the standout features of the Assa Electric Lock is its ability to incorporate various access modes. Users can choose between key-based entry, key fob access, and mobile app control. This versatility ensures that users can select the most convenient method for their specific needs while still maintaining robust security. The inclusion of a mobile application elevates user control, allowing for remote access management and real-time monitoring of lock status.

The lock is engineered with robust materials, ensuring durability and resistance to tampering. It features a high-quality housing that can withstand environmental elements, making it suitable for both indoor and outdoor installations. The Assa Electric Lock is also designed to function seamlessly with existing security systems, providing compatibility without compromising overall security.

Assa Electric Lock employs advanced encryption technologies to safeguard user data and access control commands. With encryption protocols in place, users can be confident that their security information is protected from unauthorized access. The lock also includes an audit trail feature, which logs entry and exit events, allowing property owners to track access history easily.

In addition to its electronic capabilities, Assa Electric Lock prioritizes user-friendly design. The intuitive interface and installation process make it accessible to both professional installers and DIY enthusiasts. Furthermore, the lock is equipped with a backup key option, ensuring that users can always access their property in the event of a power failure or technical issues.

The lock's energy efficiency is another key characteristic, as it operates on low power consumption without sacrificing performance. This commitment to sustainability not only reduces costs but also minimizes the environmental impact.

Overall, the Assa Electric Lock stands out in the evolving landscape of security technology. It combines traditional reliability with modern electronic features, making it an ideal choice for those seeking enhanced security solutions. With its range of access options, robust materials, advanced encryption, and user-friendly design, the Assa Electric Lock is leading the way in secure access control.