III. Power Information
Protection
Over Power Protection (OPP): | 105% to 140% | |
Over Voltage Protection (OVP): | +5V: | 5.58V to 6.82V |
| +12V: | 12.8V to 14.50V |
| +3.3V: | 3.7V to 4.80V |
Short Protection: | All outputs shorted to ground are protected. | |
Efficiency: | 70% Min |
|
Environment
Ambient Operation Temperature: 0˚C to 50˚C
Ambient Operation Relative Humidity: 20% to 80% |
| |
Insulation Resistance: | Input to Ground | 50M |
| Input to Output | 50M |
Dimension: LxWxH: | 150mm x 140mm x 86mm | |
Weight: | 1.8Kgs |
|
Hi-Pole
Input to Output | 1,800VAC | 3Sec |
Input to Ground | 1,800VAC | 3Sec |
Certifications
Approval Date | Safety Approval | Certificate Number |
CE (Nemko) | 9708001E | |
CB | 4052 | |
VDE | 95325 | |
UL | (pending) | |
CSA | (pending) | |
Nemko | 199734114 | |
Semko | ||
Demko | 306976 | |
Fimko |