2-8 Chapter 2: Installation
2.4 BIOS conguration
You need to adjust the settings in the BIOS setup of the remote server for correct
conguration and connection to the central server.
Update the remote server BIOS le following the instructions in the
motherboard/system user guide. Visit the ASUS website (www.asus.com)
to download the latest BIOS le for the motherboard.
The BIOS setup screens shown in this section are for reference purposes
only, and may not exactly match what you see on your screen.

2.4.1 Running the BIOS BMC conguration

To congure the BMC in the BIOS:
1. Restart the remote server, then press <Del> during POST to enter the BIOS
setup.
2. Go to the Server Mgmt menu, then select the BMC network conguration
sub-menu. Use this sub-menu to congure the BMC settings.
3. When nished, press <F10> to save your changes and exit the BIOS setup.

2.4.2 BMC network conguration

Allows you to set the BMC LAN Parameter settings.
: Select Screen
: Select Item
Enter: Select
+/—: Change Opt.
F1: General Help
F9: Optimized Defaults
F10: Save ESC: Exit
Version 2.01.1204. Copyright (C) 2010 American Megatrends, Inc.
Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc.
Main Server Mgmt Event Logs Advanced Monitor Boot Tool Exit
BMC Firmware Version : 1.02
FRB-2 Timer timeout [6 minutes]
FRB-2 Timer Policy [Reset]
O/S Watchdog Timer [Disabled]
O/S Wtd Timer Timeout [10 minutes]
O/S Wtd Timer Policy [Reset]
System Event Log
BMC network configuration
Enable/Disable interfaces to