ASUS ASMB6-iKVM 4-19
PEF Management LAN Destination PageThis page is used to congure the Event lter, Alert Policy and LAN destination. A
sample screenshot of PEF Management LAN Destination Page is given below.
The elds of PEF Management – LAN Destination Tab are explained below.
1. LAN Destination: Displays Destination number for the newly congured
entry (read-only).
2. Destination Type: Destination type can be either an SNMP Trap or an Email
alert. For Email alerts, the 3 elds - destination Email address, subject and
body of the message needs to be lled. The SMTP server information also
has to be added - under Conguration->SMTP. For SNMP Trap, only the
destination IP address has to be lled.
3. Destination Address: If Destination type is SNMP Trap, then enter the IP
address of the system that will receive the alert. Destination address will
support the following:
- IPv4 address format.
- IPv6 address format.
If Destination type is Email Alert, then give the email address that will receive the
email.
4. Subject & Message: These elds must be congured if email alert is chosen
as destination type. An email will be sent to the congured email address in
case of any severity events with a subject specied in subject eld and will
contain the message eld's content as the email body.
5. Add: To save the new LAN destination and return to LAN destination list.
6. Cancel: To cancel the modication and return to LAN destination list.