5.2.8Enabling WriteCache
You may manually enable the RAID controller’s WriteCache option after creating a RAID set to improve the data transmission performance.
When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives.
The WriteCache function is recommended for RAID 1 and RAID 10 sets.
To enable WriteCache
1.From the Management Menu, select Objects > Adapter, select an existing adapter, and then press <Enter> to display the adapter properties.
2.LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
|
|
|
|
|
| ||
|
|
|
| Adapter 0 |
| ||
|
| Objects | Rebuild | Rate | = 30 |
| |
Management Menu | Chk Const Rate | = 30 |
| ||||
Configure | Adapter | FGI Rate | = 30 |
| |||
Virtual Drive |
| ||||||
Initialize | BGI Rate | = 30 |
| ||||
Physical Drive |
| ||||||
Disk WC | = Off | ||||||
Objects | |||||||
|
| Read Ahead | = On | ||||
Rebuild |
|
| |||||
|
| Bios State | = Enable | ||||
Check Consistency |
| ||||||
| Cont On Error | = Yes | |||||
|
|
| |||||
|
|
| Fast Init | = Enable | |||
|
|
| Auto Rebuild | = On | |||
|
|
| Auto Resume | = Enable | |||
|
|
| Disk Coercion | = 1GB | |||
|
|
| Factory Default |
|
|
Disk Write Cache - Off(Write Through or On(Write Back)
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
3.From the Management Menu, select Objects > Virtual Drive, select an existing adapter and press <Enter>. Select View/Update Parameters and press <Enter> to display the adapter properties.
4.Select Disk WC, and then press <Enter> to turn on the option.
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
|
|
|
|
|
| ||
|
|
|
| Virtual Drive |
| ||
|
| Objects | RAID |
| = 0 |
| |
Management Menu | Size | = 148.580GB | |||||
Configure | Adapter | Stripe Size | = 64KB | ||||
Virtual Drive | |||||||
Initialize | #Stripes | = 2 |
| ||||
Physical Drive |
| ||||||
State | = OPTIMAL | ||||||
Objects | |||||||
|
| Spans | = 1 |
| |||
Rebuild |
|
|
| ||||
|
| Disk WC | = On | ||||
Check Consistency |
| ||||||
| Read Ahead | = On | |||||
|
|
|
Disk Write Cache Setting of VD
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
5.When finished, press any key to continue.