Decoder for Atlas N Scale H15/16-44 Locomotives

7

Configuration Variables and their Definitions

The H15/16-44 decoder supports a full range of features, which are activated by setting Configuration Variables. All CVs are numbered. These numbers are used during programming and are identical for all decoders that conform to NMRA standards, regardless of the decoder manufacturer. The following table lists the CVs supported in the H15/16- 44 decoder. Both CV numbers and Register numbers are provided for cross-reference.

Some CVs (such as CV29) have specific meanings for each bit. To conform to the NMRA convention for bit numbering, the CV bit assignments shown in this table use the bit-numbering scheme of 0 to 7.

Table 1: Configuration Variables (CVs) for the H15/16-44 Decoder

 

CV

Reg.

Description

Range

Default

 

 

 

 

 

Value**

 

1

1

Short address:

1-99

3

 

 

 

 

This is the number that you enter into your DCC

 

 

 

 

 

 

system to tell it which locomotive you wish to run

 

 

 

 

 

 

with a short (2-digit) address.

 

 

 

 

2

2

Start voltage:

0-31

8

 

 

 

 

This is the voltage applied to the motor in speed

 

 

 

 

 

 

step 1. Set this value so that the locomotive is

 

 

 

 

 

 

barely moving in speed step 1.

 

 

 

 

3

3

Acceleration Momentum:

1-255

1

 

 

 

 

Determines the rate of change of speed upon

 

 

 

 

 

 

acceleration. A higher value leads to a slower

 

 

 

 

 

 

acceleration.

 

 

 

 

4

4

Brake Momentum:

1-255

1

 

 

 

 

Determines the rate of change of speed upon

 

 

 

 

 

 

braking. A higher value leads to longer braking

 

 

 

 

 

 

distances.

 

 

 

 

-

5

Contains CV29 (see definition of CV29 below)

0-55

6

 

 

-

6

Page Register:

0-127

1

 

 

 

 

Normally this Register is not modified directly by

 

 

 

 

 

 

a user. For correct operation, R6 should be set to

 

 

 

 

 

 

have the value “1” after any use.

 

 

 

 

7

7

Version Number:

-

46

 

 

 

 

This location stores the version number of the

 

 

 

 

 

 

decoder. This CV is read-only.

 

 

 

 

 

 

 

 

 

 

 

 

 

Atlas Model Railroad Co., Inc.

Page 7
Image 7
Atlas 520099 manual Reg Description Range Default Value Short address, Start voltage, Acceleration Momentum, Brake Momentum