Atlas MLGC240B manual Operation, Features, Requirements, Mode Switching Summary, On-Time, Test

Models: MLGC240B MLGC240W

1 4
Download 4 pages 7.09 Kb
Page 1
Image 1
GUARDIAN PRO™

GUARDIAN PRO

240 SERIESModels MLGC240B

MLGC240W

Features

Turns on lighting when motion is detected.

Automatically turns lighting off.

Dual Light Level

Photocell keeps the lighting off during daylight hours.

LED indicates motion was sensed (day or night).

This package includes:

Lamp Holders

OPERATION

Mode:

On-Time:

Works: Day

Night

 

 

 

 

Test

5 Seconds

x

x

Auto

1, 5, 20 min.

 

x

 

 

 

 

Manual

Until Dawn*

 

x

 

 

 

 

Accent

3, 6 Hr, to Dawn

 

x

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put ON-TIME switch on the sensor bottom to TEST and the Dual Light Level switch OFF.

ON-TIME

DUAL LIGHT LEVEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST 1 5 20

Off 3 6 Dusk to Dawn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO

Put the ON-TIME switch in the 1, 5, or ON-TIME20 minute position.240 SERIESModels MLGC240BFeaturesOPERATION

20 5 1 TEST

MANUAL MODE

 

2 Shells

Cover

 

6 Screws

Sensor

(3 sizes included)

Plate

 

Light Control

2 Wire

Connectors

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one sec- ond then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 20 position.

1 Second OFF

then...

Mounting Bolt

Gasket

Mounting Strap

Rubber Plug

Plastic Hanger

Requirements

The Light Control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

© 2003 Atlas Lighting Products, Inc.

... back on.

Mode Switching Summary

TEST Test Move ON-TIME Switch to 1, 5, or 20 minutes

 

AUTO

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

for one second then
MANUAL MODE

 

 

back on*

 

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.

Dual Light Level Control

Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 20 minutes) then returns to dim mode.