Wall Plate Installation

There are four pieces that will need to be interconnected in order for the AT-HDWP-IR-UK to be
installed in the wall. The electrical box (picture A), the HDBaseT module (picture B), the face plate
(picture C) and the CAT cable.
Next, route the CAT cable through the electrical box (as seen above) and connect it to the back of
the HDBaseT module (see picture on top of page 6).
ABC
First, remove the face plate from the HDBaseT module. To do this, remove the four 4mm screws on
the sides (as pictured above).
Note: Avoid contact with the PCB board (see picture B) in the HDBaseT module, electrostatic
discharge (ESD) may damage sensitive chips.
atlona.com Toll free: 1-877-536-3976
Local: 1-408-962-0515