RS232

The Atlona AT-PROHD82M switcher can be controlled via the RS-232 serial control port to allow for interfacing to a PC, or similar third party control system.

The serial communication parameters are 9600 baud, 8 bit no parity and 1 stop bit. This is often referred to as 9600 8N1. When the unit recognizes a complete command it will perform the requested action. There is no delimiter character required.

The unit does not send out a message when a value is changed from the front panel or by IR control. If the switcher needs to be controlled in addition to the RS-232 control, you should regularly verify the unit’s status to

RS 232 SERIAL COMMANDS

1. Protocol Commands

All#

Transfer all input signals to matching output channels.

 

 

[x1] AV[x2]

Transfer the audio and video signals from input channel [x1] to

 

 

 

output channel [x2]. Example: input 5 needs to be send to output 6,

 

the commands would be x5AVx6

 

 

[x1] AV[x2],[x3],[x4]

Transfer the audio and video signals from input channel [x1] to output

 

channels [x2], [x3] and [x4].

 

 

[x1] A[x2]

Transfer the audio signals from input channel [x1] to output channel [x2].

 

Example: input 5 needs to be send to output 6, 8, 10, 15

 

the commands would be x5AVx6,x8,x10,x15

 

 

Save[Y]

Save the present operation to the preset command [Y]. [Y] ranges from 0 to 9.

 

 

Recall[Y]

Recall the preset command [Y].

 

 

Vol100, Vol101,

Volume adjustment on output # 1

Vol102, Vol103,

 

Vol104, Vol105,

 

Vol106, Vol107,

 

Vol108, Vol109,

 

Vol110

 

 

 

Vol200, Vol201,

Volume adjustment on output # 2

Vol202, Vol203,

 

Vol204, Vol205,

 

Vol206, Vol207,

 

Vol208, Vol209,

 

Vol210

 

 

 

Clear[Y]

Clear the preset command [Y].

 

 