22
MaxBurstLength
The maximum SCSI data payload, in bytes, in a Data-In
or a solicited Data-Out iSCSI sequence. A sequence
consists of one or more consecutive Data-In or Data-Out
PDUs that end with a Data-In or Data-Out PDU with the
F bit set to one.
ATTO value: 1048576 decimal 00100000 hex
MaxRecvDataSegmentLength
The maximum data segment length, in bytes, that a
transmitter (initiator or target) can receive in an iSCSI
PDU. The transmitter is required to send PDUs with a
data segment that does not exceed
MaxRecvDataSegmentLength
of the receiver.
ATTO value: 1048576 decimal 00100000 hex
MaxTransferLength
The maximum number of bytes that may be transferred by
a single SCSI request block (SRB).
ATTO value 1048576 decimal 00100000 hex
SrbTimeoutDelta
The maximum amount of time, in seconds, before an SRB
request will time out.
ATTO value 300 decimal 0000012c hex
Tcp1323Opts
This parameter controls RFC 1323 time stamps and
window-scaling options. Time stamps and window
scaling are enabled by default, but can be manipulated
with flag bits. Bit 0 controls window scaling and bit 1
controls time stamps.
ATTO value: 1

Optimize ATTO ExpressNAV in Internet

Explorer

1 Go to the browser toolbar and select Tools
2Select Internet Options
3 Select the Security tab
4 Select the Custom Level button.
5 On the menu presented, go to the Microsoft
VM, Java permissions and make sure
Disable Java is not selected.
6 Go to the Miscellaneous topic and select
METAREFRESH.
Reset to factory defaults
A manual reset switch is mounted on the back panel.
Insert a tool in the hole in the back panel to activate the
switch, wait until the Activity LED on the top of the
iPBridge becomes green, then cycle power. The
iPBridge is reset to factory defaults.