ATTO FibreBridge™ 4500R/D
Fibre Channel and SCSI
Fibre Channel Interface:
¥
¥Three (3) independent SC optical ports
¥Full support for direct connect to
¥Class 2, Class 3 ANSI Fibre Channel specifications
¥PLDA, public loop login (NL_ports) and fabric direct connect (N_port)
¥
¥FC Chip: Qlogic ISP2200A
SCSI Interface:
¥Four (4) independent VHDCI SCSI connectors
¥Supports LVD Ultra2 or HVD UltraSCSI
¥LVD Ultra2 SCSI Ð 80 MB/sec. max. per channel
¥HVD UltraSCSI Ð 40 MB/sec. max. per channel
¥Backward compatible with all
¥128 LUNs per channel
¥HVD SCSI Chip: LSI Logic SYM53C896
¥LVD SCSI Ship: LSI Logic SYM54C1010
Performance:
¥Up to 1.5 TB/hr.
¥300 MB/sec. maximum
¥Up to 280 MB/sec. sustained
¥Memory: 64 MB of SDRAM
¥Support for 2 concurrent XCOPY commands
Fibre Channel Compliance:
¥ANSI
¥SNIA Extended Copy
¥Class 2 and Class 3
Management
Device Management Physical Interface:
¥
¥Serial through
¥Network through 10/100 BaseT Ethernet Port (Telnet, FTP and SNMP)
Figure 2 - Rear Panel View
Fibre Channel Ports
Ethernet Port | SCSI Ports | |
Serial Port |
|
|
Device Management User Interface: |
| Configuration: |
¥ Command Line Interface (CLI) |
| ¥ Desktop (with attached feet) |
¥ |
| ¥ 19" Rack mount kit included (mounting |
¥ ATTO BridgeToolsª | brackets) | |
¥ Tag Command Queuing supported |
| Airflow: |
¥ Performance reporting/Error logging |
| |
| ¥ Internal fans provide 11 CFM | |
|
| |
LEDs: |
| internal air flow |
| ¥ Ambient air not to exceed 70¼ C | |
¥ Power |
| |
| ¥ Front to back | |
¥ Ready |
| ¥ Optional side to side |
¥ Fault |
| Other |
¥ FC activity port 0, 1, 2 |
| |
¥ SCSI activity bus 0, 1, 2, 3 |
| Operating Systems Supported: |
Environmental and Physical |
| ¥ Operating system independent |
| Agency Certifications: | |
Characteristics |
| |
| ¥ FCC Class A | |
|
| |
Dimensions: |
| ¥ CE (EN55022/EC50082) |
16.725" W |
| ¥ CSA |
|
| |
10.000" L |
| ¥Flash: 2 qty. |
1.720" (1U) H |
| |
| ration and i906, 2200 and 896/1010 | |
|
| |
Operating Environment: |
| firmware |
¥ Temperature: |
| ¥ Internal 66 MHz PCI bus |
¥ Humidity: |
|
|
Power:
¥Input:
Max 2.0 A @ 110 VAC
¥Rated:
Backup Method |
|
|
| ||
¥ Reset button | Serverless | Provides 95% |
|
|
|
| CPU Availability | 1 |
|
| |
|
|
|
| ||
| Standard | Provides 45% |
|
| |
|
|
|
| ||
| CPU Availability |
|
| 1 | |
|
|
| 4 | ||
|
|
|
| ||
|
|
|
|
| |
| 2 |
| 5 |
| 2 |
|
| 4 |
| ||
| 3 |
|
| 3 |
Figure 1 - Serverless Backup
F i b r e C h a n n e l