6. ELECTRICAL DATA

6. ELECTRICAL DATA

6-1. Electrical Characteristics

Indoor unit

KGS1411

 

 

 

 

 

 

Outdoor unit

CG1411

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor

Fan Motor

Compressor

 

 

 

 

 

 

 

 

 

Performance at

 

 

 

 

115V Single phase 60Hz

 

 

 

 

 

 

 

 

Rating conditions

Running amp.

A

0.35

0.64

7.2

8.2

 

 

Power input

kW

0.033

0.077

0.79

0.90

 

 

 

 

 

 

 

Full load conditions

Running amp.

A

0.35

0.64

9.0

10.0

 

 

Power input

kW

0.033

0.077

0.99

1.10

 

 

 

 

 

 

 

 

Rating conditions: Indoor air temperature

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

Outdoor air temperature

95°F (35°C) D.B.

Full load conditions: Indoor air temperature

95°F (35°C) D.B. / 70°F (21.2°C) W.B.

Outdoor air temperature

115°F (46.1°C) D.B.

Heating

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

 

 

 

 

 

Fan Motor

Fan Motor

Compressor

 

 

 

 

 

 

 

 

Performance at

 

 

 

115V Single phase 60Hz

 

 

 

 

 

 

 

 

Rating conditions

Running amp.

A

0.35

0.64

4.9

5.9

 

Power input

kW

0.033

0.077

0.51

0.62

 

 

 

 

 

 

 

Full load conditions

Running amp.

A

0.35

0.64

5.8

6.8

 

Power input

kW

0.033

0.077

0.61

0.72

 

 

 

 

 

 

 

Rating conditions: Indoor air temperature

70°F (21.1°C) D.B.

Outdoor air temperature

47°F (8.3°C) D.B. / 43°F (6.1°C) W.B.

Full load conditions: Indoor air temperature

80°F (26.7°C) D.B.

Outdoor air temperature

75°F (23.9°C) D.B. / 65°F (18.3°C) W.B.