Sanyo KGS1411 service manual Outdoor Unit, Outdoor unit CG1411

Models: KGS1411 CG1411

1 100
Download 100 pages 10 Kb
Page 9
Image 9
2-2-2. Outdoor Unit (1)

2-2-2. Outdoor Unit (1)

Outdoor unit CG1411

Control PCB

Part No.

Controls

Control circuit fuse

Gas Connection

Employed gas

Gas connection

CG1411

Microprocessor

115V 5A

Natural Gas (LP)

1/2 Female

Compressor

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

Rotary (Hermetic)

 

Compressor model

 

 

C-1R71H2W

 

 

 

 

 

 

 

Nominal output

 

 

W

700

 

 

 

 

 

 

Compressor oil … Amount

 

cc

SUNISO 4GSD-T … 370

 

 

 

 

 

Coil resistance (ambient temp. 68°F (20°C))

Ω

C – R: 0.879

 

 

 

 

 

C – S: 3.609

 

 

 

 

 

 

 

Safety devices

Type

 

 

External (OLR)

 

 

 

 

 

 

 

 

Overload relay

 

 

MRA98962-9200

 

 

 

 

 

 

 

Operating temp.

Open °F (°C)

275 ± 9 (135 ± 5)

 

 

 

Close °F (°C)

156 ± 20 (69 ± 11)

 

 

 

 

 

 

Operating amp (ambient temp. 77°F (25°C))

Trip in 6 to 16 sec. at 34A

 

 

 

 

 

 

 

Run capacitor

 

 

µF

35

 

 

 

 

VAC

330

 

 

 

 

 

 

 

PTC starter

Part number

 

 

912X24E400XR20-PS2A

 

 

Resistance

 

Ω

47

 

 

Max voltage

 

 

300

 

 

 

 

 

 

Crank case heater

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan & Fan Motor

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

Propeller

 

 

 

 

 

Q’ty … Dia. and length

inch. (mm)

1 … 13-25/32 (ø 350)

 

 

 

 

 

 

Fan motor model … Q’ty

 

 

SB6-11H1P … 1

 

 

 

 

 

 

No. of poles … rpm (115V, High)

 

 

6 … 600

 

 

 

 

 

 

 

Nominal output

 

 

W

10

 

 

 

 

 

Coil resistance (ambient temp. 77°F (25°C))

Ω

BLU – BRN: 114.0 ± 7%

 

 

 

 

 

BLU – WHT: 153.4 ± 7%

 

 

 

 

 

 

 

Safety devices

Type

 

 

Thermostat

 

 

 

 

 

 

 

Operating temp.

Open °F (°C)

266 ± 14 (130 ± 8)

 

 

 

Close °F (°C)

174 ± 27 (79 ± 15) Automatic reclosing

 

 

 

 

 

 

 

Run capacitor

 

 

µF

5.0

 

 

 

 

VAC

220

 

 

 

 

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

 

 

Coil

 

 

 

Aluminum plate fin / Copper tube

 

 

 

 

 

 

 

Rows

 

 

 

1

 

 

 

 

 

 

Fin pitch

 

inch (mm)

1/16 (1.3)

 

 

 

 

 

 

 

Face area

 

 

ft2 (m2)

2.73 (0.254)

External Finish

Acrylic baked-on enamel finish

DATA SUBJECT TO CHANGE WITHOUT NOTICE.