11-3. Checking Electrical Components

11-3-1. Components

Flow

 

Measurement Target

 

 

(Normal) Upper: Volt, Amp.

Remarks

 

 

 

 

 

 

 

 

 

 

 

 

No.

 

CO. No.

 

Wire Color

(Normal) Lower: Resistance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

T

 

WHT – BLU

DC

1 – 12 (Pulse)

Flap motor

 

 

 

300 – 450 Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLU – BRN

AC

100 – 130 V

 

2

 

S

 

 

30 – 60 Ω

 

 

Indoor fan motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED – BLU

DC

1 – 12V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

More than 3000 Pulse/min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50°F (10°C)

9.0 – 11.0 kΩ

Indoor

3

 

Z

 

1WHT – GRY2

68°F (20°C)

5.5 – 7.0 kΩ

 

 

room temperature sensor

 

 

 

 

 

 

 

 

86°F (30°C)

3.5 – 4.5 kΩ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

U

 

3BLK – BLK4

50°F (10°C)

100 – 120 kΩ

Indoor

 

 

68°F (20°C)

50 – 60 kΩ

coil temperature sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

B

 

BLK – BLK

AC

100 – 130 V

Reversing valve

 

 

 

300 – 400 Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK – WHT

1 – 5 Ω

 

 

 

6

 

R

 

WHT – PNK

 

 

Compressor

 

 

 

 

 

BLK – PNK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

Terminal block

 

WHT

3 – 5 A

 

 

Ampere current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68°F (20°C)

9.8 – 10.8 KΩ

Outdoor

8

 

KM

 

BLK – BLK

86°F (30°C)

6.8 – 7.3 KΩ

 

 

thermistor 1, 2

 

 

 

 

 

 

 

 

140°F (60°C)

2.4 – 2.6 KΩ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

PUR – PUR

AC

30 – 115 V

Combustion blower motor

9

 

 

 

10 – 30 Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

RED – BLU

DC

1 – 5 V

 

 

Combustion blower motor

 

 

 

 

 

 

 

 

More than 1000 Pulse/min.

fan speed sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

!

 

O

 

BLU – BLU

DC

5 – 24 V

 

 

Proportional

 

 

 

40 – 160 Ω

control valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"

 

J

 

BLK – Ground

AC

100 – 130 V

Flame sensor probe

 

 

More than DC 1 µA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#

 

P

 

YEL – YEL

Not more than DC 1 V

Thermal fuse

 

 

Not more than 1 Ω

bimetal thermostat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

$

 

I

 

WHT – WHT

DC

90 – 120 V

Gas valve 1

 

 

 

1 – 2.5 kΩ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

%

 

I

 

ORG – ORG

DC

90 – 120 V

Gas valve 2

 

 

 

1 – 2.5 kΩ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

&

 

G

 

RED – RED

AC

100 – 130 V

Ignition transformer

 

 

 

 

 

 

 

 

 

 

 

 

(

 

E

 

BLK – BLK

AC

100 – 130 V

ON/OFF valve 1

 

 

 

300 – 500 Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

)

 

F

 

BLK – BLK

AC

100 – 130 V

ON/OFF valve 2

 

 

 

300 – 500 Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

WHT – BLU

AC

100 – 130 V

 

 

 

 

 

 

 

 

 

 

 

 

~

 

V

 

WHT – BRN

 

70 – 150 Ω

Outdoor fan motor

 

 

 

WHT – PNK

 

300 – 500 Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

W

 

PNK – PNK

Not more than AC 1 V

Overload relay

 

 

Not more than 1 Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation

 

 

Outdoor Unit Voltage at Terminal Block

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2

 

1 3

 

1 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling • Dry

 

100 – 130 V

 

100 – 130 V

0 V

 

 

 

 

 

 

 

 

 

 

 

 

Heating

 

100 – 130 V

 

100 – 130 V

100 – 130 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

0 V

 

100 – 130 V

0 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 