13. SPECIAL PRECAUTIONS WHEN SERVICING THE UNIT
Important!
For your personal safety, be sure to read and understand the following precautions before servicing.
Injuries can occur from burns or inhalation of toxic gas if servicing is per-
WARNING formed while refrigerant remains in the refrigeration circuit. This servicing includes disassembling brazed tubing connections and removing any refrigeration parts or components.
●To avoid risk of injury when servicing the outdoor unit (for instance, when replacing the compressor or repair- ing a refrigerant leak), follow the procedure below for the refrigerant circuits of the outdoor unit.
PROCEDURE
13-1. BLK/WHT Connector Attachment for Servicing
Important!
The procedures given in
●Condition at shipping and operation
Black
White
V2
CN4 | CN6 |
|
Outdoor PCB
V1
●Condition at servicing
Power supply
AC115V
Connectors for servicing Disconnect switch (Field supply)
Special connector
Black
White
|
| V2 |
CN4 | CN6 | V1 |
|
Outdoor PCB
Fig. 1
65