13-6. Reattaching BLK/WHT Connectors for Operation

13-5-5.If it is not possible to completely charge the unit with the proper amount of refrigerant, you can do an additional charging after installing the units. At that time, refrigerant should be recharged in the liquid state a little at a time using the wide tube service port, and the air conditioner should be operating in COOLING mode during the entire charging process.

NOTE

Charging the unit with a large amount of refrigerant at once may damage the compressor. Always charge the unit at a constant charging rate of about 0.2 lb (100 g).

13-6. Reattaching BLK/WHT Connectors for Operation

13-6-1.Turn off the power source.

13-6-2.Connect the BLK/WHT connectors to each other as in the original state.

CAUTION

Remember to reattach the BLK/WHT connectors in their original position. Otherwise, the system will not operate correctly and damage may occur.