Dimensions & Weight

Indoor unit

KGS1411

 

 

 

 

 

 

 

 

Outdoor unit

CG1411

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions & Weight

 

 

 

Indoor Unit

 

Outdoor Unit

 

 

 

 

 

 

 

 

 

Unit dimensions

Height

 

inch (mm)

10-5/8 (270)

 

23-7/32 (590)

 

 

 

Width

 

inch (mm)

31-11/16 (805)

 

28-1/2 (724)

 

 

 

Depth

 

inch (mm)

6-31/32 (177)

 

11-15/32 (291)

 

 

 

 

 

 

 

 

 

Package dimensions

Height

 

inch (mm)

9-13/16 (249)

 

31-1/16 (789)

 

 

 

Width

 

inch (mm)

33-21/32 (855)

 

25-1/32 (636)

 

 

 

Depth

 

inch (mm)

13-5/16 (338)

 

14-29/32 (379)

 

 

 

 

 

 

 

 

 

 

Weight

 

Net

 

lb. (kg)

17.6 (8.0)

 

85.7 (39.0)

 

 

 

Shipping

 

lb. (kg)

22.0 (10.0)

 

90.8 (41.0)

 

 

 

 

 

 

 

 

 

Shipping volume

 

 

cu.ft (m3)

2.51 (0.071)

 

6.72 (0.19)

 

 

 

 

 

 

 

 

 

Burner

 

 

 

 

Natural gas

 

 

LP

 

Burner type

 

 

 

 

Ribbon burner

 

 

 

 

 

 

 

 

 

 

Burner configuration

 

 

 

 

Slit type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Consumption

 

 

 

Natural gas

 

 

LP

 

 

 

 

 

 

 

 

 

Typical input

BTU/h (kW)

 

High

15,500 (4.55)

 

15,500 (0.719 lb./h)

 

 

 

 

 

Medium

10,400 (3.05)

 

10,400 (0.482 lb./h)

 

 

 

 

 

Low

6,150 (1.80)

 

6,150 (0.285 lb./h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Governor Setting Pressure

 

 

 

Natural gas

 

 

LP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2

P1

 

P2

P1

 

 

 

 

 

 

 

 

 

 

P2, P1

Inches water column (kPa)

High

3.43 (0.853)

7.0 (1.74)

 

3.54 (0.883)

11.0 (2.74)

 

 

 

 

 

Medium

1.61 (0.402)

"

 

1.61 (0.402)

"

 

 

 

 

 

Low

0.63 (0.157)

"

 

0.63 (0.157)

"

 

 

 

 

 

 

 

 

 

 

 

Gas Nozzle

 

 

 

 

Natural gas

 

 

LP

 

 

 

 

 

 

 

 

Inner diameter

 

ø inch (ø mm)

0.0807 (2.05)

 

0.0630 (1.60)

 

 

 

 

 

 

 

 

 

 

 

 

Q’ty

 

 

 

 

 

1

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety Devices

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

 

Re-start timer (3 minute)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor over-load limiting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Circuit fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

Current limit function (out of range between 0.8 – 17A)

 

 

 

 

Thermal fuse

 

 

 

 

 

 

 

Auto reset temperature limiting 221°F (105°C)

 

 

 

 

Flame rod

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Remarks: Rating conditions are

 

 

 

 

 

 

 

 

 

Cooling: Indoor air temperature

80°F D.B. / 67°F W.B.

 

 

 

 

 

 

Outdoor air temperature

95°F D.B. / 75°F W.B.

 

 

 

 

 

Heating: Indoor air temperature

70°F D.B.

 

 

 

 

 

 

 

Outdoor air temperature

47°F D.B. / 43°F W.B.

 

 

 

 