2-3-2. Outdoor Unit Outdoor unit CG1411
Transformer (TR) |
| 4FF4L510034000 |
|
|
|
|
|
|
|
Rating | Primary | AC 115V, 60Hz |
|
|
| Secondary S1 | DC 25.4V, 0.25A |
|
|
| S2 | DC 12.6V, 0.1A |
|
|
| S3 | AC 100V, 1Ma |
|
|
| Capacity | 5VA |
|
|
|
|
|
| |
Coil resistance | Ω (at 70°F (21°C)) | Primary (ORG – ORG): | 71.1 ± 10% | |
|
| Secondary (RED – RED): 5.79 | ± 10% | |
|
| Secondary (BLU – BLU): | 8.38 | ± 10% |
|
| Secondary (YEL – YEL): | 257 | ± 10% |
|
|
|
|
|
Thermal |
| 277°F (136°C) |
|
|
|
|
|
|
|
Power Relay (PR) |
| DFU24D1F |
|
|
|
Coil rating |
| DC 24V |
|
|
|
Coil resistance | Ω (at 68°F (20°C)) | 650 ± 10% |
|
|
|
Contact rating |
| AC 250V, 20A |
|
|
|
Thermistor 1 (Discharge pressure) | ||
|
|
|
Resistance | kΩ | 122°F (50°C) 2.2 ± 5% |
|
| |
|
| |
Thermistor 2 (Outlet refrigerant temp.) | ||
|
|
|
Resistance | kΩ | 131°F (55°C) 2.2 ± 5% |
|
|
|
|
|
|
Reversing Valve |
| |
|
|
|
Coil rating |
| AC115 – 120V, 50/60Hz, 6/5W |
|
|
|
Coil resistance | Ω | 370 |
|
|
|
|
|
|
ON/OFF Valve (Q’ty = 2) |
| |
|
|
|
Coil rating |
| AC115 – 120V, 50/60Hz, 7W |
|
|
|
Coil resistance | Ω | 370 |
|
| |
|
| |
Check Valve 1 (See Refrigerant Diagram) | ||
|
| |
Check Valve 2 (See Refrigerant Diagram) | ||
|
|
|
Auto Reset Temperature Limiting |
| |
|
|
|
Model |
| |
|
|
|
Rating |
| AC125V, 200mA |
|
|
|
Thermal Fuse
Model
X25
293°F (145°C)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
8