Sanyo KGS1411 service manual Outdoor Unit Outdoor unit CG1411

Models: KGS1411 CG1411

1 100
Download 100 pages 10 Kb
Page 12
Image 12
2-3-2. Outdoor Unit Outdoor unit CG1411

2-3-2. Outdoor Unit Outdoor unit CG1411

Transformer (TR)

 

4FF4L510034000

 

 

 

 

 

 

 

Rating

Primary

AC 115V, 60Hz

 

 

 

Secondary S1

DC 25.4V, 0.25A

 

 

 

S2

DC 12.6V, 0.1A

 

 

 

S3

AC 100V, 1Ma

 

 

 

Capacity

5VA

 

 

 

 

 

 

Coil resistance

Ω (at 70°F (21°C))

Primary (ORG – ORG):

71.1 ± 10%

 

 

Secondary (RED – RED): 5.79

± 10%

 

 

Secondary (BLU – BLU):

8.38

± 10%

 

 

Secondary (YEL – YEL):

257

± 10%

 

 

 

 

 

Thermal cut-off temp.

 

277°F (136°C)

 

 

 

 

 

 

 

Power Relay (PR)

 

DFU24D1F

 

 

 

Coil rating

 

DC 24V

 

 

 

Coil resistance

Ω (at 68°F (20°C))

650 ± 10%

 

 

 

Contact rating

 

AC 250V, 20A

 

 

 

Thermistor 1 (Discharge pressure)

PB3M-41E

 

 

 

Resistance

kΩ

122°F (50°C) 2.2 ± 5%

 

 

 

 

Thermistor 2 (Outlet refrigerant temp.)

PB3M-41E

 

 

 

Resistance

kΩ

131°F (55°C) 2.2 ± 5%

 

 

 

 

 

 

Reversing Valve

 

CHV-01AE (Coil), CHV-0101 (Valve)

 

 

 

Coil rating

 

AC115 – 120V, 50/60Hz, 6/5W

 

 

 

Coil resistance

Ω

370

 

 

 

 

 

 

ON/OFF Valve (Q’ty = 2)

 

NEV-MOAE (Coil), NEV-603DXF (Valve)

 

 

 

Coil rating

 

AC115 – 120V, 50/60Hz, 7W

 

 

 

Coil resistance

Ω

370

 

 

 

 

Check Valve 1 (See Refrigerant Diagram)

FCV-3020D

 

 

Check Valve 2 (See Refrigerant Diagram)

BCV-804DX

 

 

 

Auto Reset Temperature Limiting

 

 

 

 

Model

 

CS-7L

 

 

 

Rating

 

AC125V, 200mA

 

 

 

Thermal Fuse

Model

Cut-off temp.

X25

293°F (145°C)

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

8

Page 12
Image 12
Sanyo KGS1411 service manual Outdoor Unit Outdoor unit CG1411