Sanyo KGS1411, CG1411 service manual Combustion Saving Function, Save Function, Reset Function

Models: KGS1411 CG1411

1 100
Download 100 pages 10 Kb
Page 39
Image 39
8-3-3. Combustion Saving Function

8-3-3. Combustion Saving Function

After Thermo. OFF occurs, shifts to Continuous Combustion Mode, Save Mode 1, or Save Mode 2, according to the load inside the room.

<Normal Combustion Mode>

Performs combustion which is proportionally controlled by setting the maximum amount of gas equivalent to the amount of rated combustion.

<Save Mode 1>

Performs combustion which is proportionally controlled by setting the maximum amount of gas to about 70% of the rated amount of combustion.

<Save Mode 2>

Performs continuous combustion by setting the amount of gas equivalent to the minimum amount of com- bustion.

(1) Save Function

If Thermo. ON lasts less than 10 minutes under Normal Combustion Mode subsequent to Thermo. OFF, Save Mode 1 is automatically selected for the following Thermo. ON, and then Save Mode 2 is selected if Save Mode 1 lasts less than 10 minutes.

Thermo.

Less than

Thermo.

Less than

Thermo.

Less than

Thermo.

OFF

10 minutes

OFF

10 minutes

OFF

10 minutes

OFF

Normal Combustion

Mode

Save Mode 1

Save Mode 2

Stop combustion

(2) Reset Function

When combustion in Save Mode 1 continues past 10 minutes, it goes back to Normal Combustion Mode (Save Mode 2 to Save Mode 1). However, if Thermo. OFF occurs again within 10 minutes under Normal Combustion Mode, Save Mode 1 is selected at the next Thermo. ON (Save Mode 1 to Save Mode 2).

Thermo. 10 minutes

10 minutes

Less than

Thermo. 10 minutes

OFF

 

10 minutes

OFF

Normal Combustion Mode

Save Mode 1

Save Mode 2

35