7-1-2. Outdoor Unit

7-1-2. Outdoor Unit

AVOID:

heat sources, exhaust fans, etc. (Fig. 4)

damp, humid or uneven locations.

DO:

choose a place as cool as possible.

choose a place that is well ventilated.

allow enough room around the unit for air intake/ exhaust and possible maintenance. (Fig. 5a)

CAUTION

Install the outdoor unit above snowfall line.

Do not place objects on or sit on the outdoor unit. Also, never block the air intake/outlet or exhaust. Distortion of the outdoor unit or incomplete combustion may result.

Touching the air exhaust can cause a burn. Take special care for children not to touch it.

Do not introduce foreign matter into the air intake/outlet or exhaust. Do not insert point- ed objects, such as sticks.

When the ambient temperature is dropping, a white cloud or fog may be seen blowing from the unit. This does not indicate a problem.

The distance between any building opening* and the exhaust must be 24 in. (60 cm) or more.

Locate the outdoor unit away from windows to avoid possible entry of exhaust gases into the building. Pay special attention to the win- dows of a neighboring house or building.

If there is a window within 24 in. (60 cm) of the exhaust, make sure it is not located inside the projected exhaust area within

24 in. (60 cm) above, within 6 in. (15 cm) below, within 6 in. (15 cm) on either side, or within 6 in. (15 cm) in front of the exhaust.

*Meaning of “building opening”

Windows or doors which can be opened, but not including those which are fixed or cannot be opened.

NO

Exhaust fan

Hot air

Heat source

Outdoor unit

Fig. 4

 

 

 

 

Obstacle above

 

 

 

(25 cm)

discharge

Min.

Min.

Air intake

Min. 6" (15 cm)

7 ft.

7 ft.

Valve side

 

 

 

 

 

(2 m)

(2 m)

 

 

 

Min. 10"

 

 

Obstacle

Min. 6" Air discharge

Min. 12"

Air

 

(15 cm)

 

(30 cm)

 

 

 

 

 

 

 

Ground

 

 

 

 

 

 

 

Min. 6 in.

 

 

Fig. 5a

 

(15 cm)

 

 

 

Air intake

 

 

 

 

 

26