Sanyo CG1411, KGS1411 service manual Outdoor Unit, Location of Service Valves

Models: KGS1411 CG1411

1 100
Download 100 pages 10 Kb
Page 14
Image 14
3-1-2. Outdoor Unit

3-1-2. Outdoor Unit

Outdoor unit CG1411

4-11/16

16-23/32

4-9/16

 

(119)

(425)

(116)

 

 

Holes for anchor bolts

 

2-9/16

 

 

(65)

 

(4-ø15/32)

 

 

 

 

10-1/4 (260)

 

 

9-1/16 (230)

 

 

 

2-13/32

 

25-31/32 (660)

 

(30)

 

 

 

 

 

5-21/32

2-17/32

 

 

(144)

(64)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-5/32

 

 

 

23/32-24(628)

 

 

7/32-23(590)

 

 

(131)

 

 

 

 

 

 

 

 

 

 

 

 

Narrow tube service valve ø1/4 (6.35)

Wide tube service valve ø3/8 (9.52)

9-1/16

(230)

2-21/32 (67.5)

2-5/32

(55)

3-5/16

(84)

Unit: inch (mm)

NOTE

Location of Service Valves

Service valves are located behind the side panel. See the illustration at right.

10-1/4

(260)

Wide tube service valve ø3/8 (9.52)

Narrow tube service valve ø1/4 (6.35)

2-1/4

(57)

3-5/16

(84)

10

Page 14
Image 14
Sanyo CG1411, KGS1411 service manual Outdoor Unit, Location of Service Valves