Atwood Mobile Products KN-COPP-B manual cont Sounds Alarm The If Do To What

Models: KN-COPP-B

1 28
Download 28 pages 17.57 Kb
Page 19
Image 19
).(cont Sounds Alarm The If Do To What

19

.ppm 30 under concentrations monoxide carbon for signals visual and audible provide which devices, warning using consider may problems medical with Individuals .practitioner medical a consult doubt, in If .conditions medical ic -specif with individuals safeguard fully not will It .exposure monoxide bon -car of of effects acute from individuals protect to designed is device This

.standards industrial and commercial with compliance measure to designed not is It .areas residential indoor ordinary in use for intended is product This

WARNING

minutes 15-4 within alarm must unit the PPM, 400 At minutes 50-10 within alarm must unit the PPM, 150 At minutes 240-60 within alarm must unit the PPM, 70 At follows: as requirements time response alarm the meets alarm CO This

.made are repairs appropriate the that and determined is CO the of source the that crucial it’s solved, temporarily be to appear may problem your Although .responds help time the by dissipated have may buildup CO the open, doors and windows your leaving by tion -ventila provided you’ve and alarmed has unit your If .problem CO existing an solve it can nor occurring, from CO prevent not does It .CO of presence the of you warn only can alarm CO This

.triggered be will alarm the sooner the present, monoxide carbon of level the higher the - alarm weighted-time a has unit Kidde This .levels high to exposures term-short as well as symptoms, cause may levels low to sures -expo term-long poison, cumulative a is monoxide carbon Because

.possible if CO of source the eliminate to action take you recommends Kidde .closely situation the watch to need a indicates This .ppm 50 below generally levels: Mild

.17 page on instructions the Follow .dismissed or ignored be not should and concern for cause be should This .ppm 100 to ppm 50 between generally levels: Mid .17 page on instructions the Follow .situation urgent an as treated be should This .symptoms experiencing one no with ppm, 100 above generally levels: Medium

).(cont Sounds Alarm The If Do To What

Niveaux de danger/d’alarme (suite)

Cette alarme de CO répond aux exigences de la norme UL 2034 en qui a trait au temps de réaction :

à70 ppm, l’alarme doit se déclencher dans un intervalle de 60-240minutes

à150 ppm, l’alarme doit se déclencher dans un intervalle de 10-50 minutes

à400 ppm, l’alarme doit se déclencher dans un intervalle de 4-15 minutes

19

Page 19
Image 19
Atwood Mobile Products KN-COPP-B manual cont Sounds Alarm The If Do To What, Niveaux de danger/d’alarme suite