Memory back-up

In the event of a power failure, an internal circuit will maintain the programming and the time. But only the time could have to be set if power failure is more than 2 hours.

Early Start function

The thermostat is providing a built-in function enabling it to calculate the optimum time to start the heating system to achieve the desired temperature setting at the programmed time. This function could start the heating system as early as 6 hours prior to the programmed time. To enable this function, set the switch E.S. to “ON” at the back of the thermostat.

PROGRAMMING

Programming the time and day

1- Set the time using the Hour and Min buttons. 2- Set the day using the Day button.

Programming the Comfort, Economy and Vacation settings

The Comfort , Economy and Vacation settings respectively represent the temperatures that you wish to have during the day , at night or while you are away at work , or while you are away for an extended period .

To program your settings

a) To program the Comfort temperature, select the desired degree using the

buttons and press the button until the icon is displayed (app. 3 seconds).

b) To program the Economy temperature, select the desired degree using the

buttons and press the button until the icon is displayed (app. 3 seconds).

c) To program the Vacation temperature, select the desired degree using the

 

buttons and press on the

and

buttons simultaneously

until the

icon is displayed (app. 3 seconds).

 

d)Press the Mode button to exit this function and return to the normal operating mode.

Schedule programming

The TH111GFCI-P allows 4 setting changes for each day of the week. There are no pre-set programs.The programs are tailored to perfectly adapt to your life style. The principle is very simple. For each day, enter the time at which you wake up (P1), the time you leave for work (P2), the time you arrive back home (P3) and the time you go to bed (P4).

Program

 

Mode

 

 

 

Time

 

1

 

 

 

 

 

 

Wake-up time

 

2

 

 

 

 

 

 

Departure time

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

Return time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

Bed time

 

 

 

 

 

 

 

 

 

 

 

NOTE : For

temperature

increases

(Prog.

1 and

3),

allow at

least

15

minutes per

°C. If you

have

lowered

the

temperature by

3 °C during the night and you wake up at

7 AM, change

the

setting at 6:15 AM.

 

 

 

 

 

 

 

For savings to be obtained, you must lower the temperature for a period of 2 to 3 times the delay required to bring the temperature back to your comfort level.

Example : If your system takes one hour to go from your saving temperature level to your comfort temperature Ievel, it is useless to lower the temperature for a period less than 3 hours.

a) To program your schedule

1- Press on PGM button to access the programming mode.

2- Press on Day button to select the day to be programmed. You can select all days of the week by pressing on Day button for 3 seconds.

3- Press on PGM button to select program 1, 2, 3 or 4.

4- Press on Hour and Min buttons to program the time.

5- When you have completed your programming, press on Mode button to exit this function.

b) To erase a program :

Select the program using PGM and Day buttons, and press on Clear button. The time field displays --:-- when the program is inactive.

c)Example 1 : Comfort period from 7:00 AM to 10:30 PM Economy period from 10:30 PM to 7:00 AM Identical schedule for all days of the week.

1- Press on PGM button to access the programming mode.

2- Press on Day button 3 seconds to select every day of the week.

3- Press on Hour button to enter 7:00 AM, Prog. 1 (

).

4-

Press on PGM button again to select Prog. 2 (

), and press on

 

Hour and Min buttons to enter 10:30 PM.

 

5-

Press on Mode button to exit this function.

 

d)Example 2 : Comfort period: Monday to Friday from 6:15 AM to 8:15 AM and from 5:00 PM to 10:00 PM.

Schedule/Day

MON.

TUES.

WED.

THU.

FRI.

SAT.

SUN.

 

 

 

 

 

 

 

 

PROG. 1

6:15 AM

6:15 AM

6:15 AM

6:15 AM

6:15 AM

7:30 AM

7:30 AM

 

 

 

 

 

 

 

 

PROG. 2

8:15 AM

8:15 AM

8:15 AM

8:15 AM

8:15 AM

---

---

PROG. 3

5 PM

5 PM

5 PM

5 PM

5 PM

---

---

PROG. 4

10 PM

10 PM

10 PM

10 PM

10 PM

11 PM

11 PM

 

 

 

 

 

 

 

 

NOTE : It is faster to program the same

schedule for every

day and then

 

modify the exception days.

 

 

1-

Press on PGM button to access the programming mode.

 

2- Press on Day button 3 seconds to select every day of the week.

3-

Press on Hour and Min buttons to enter 6:15 AM Prog. 1, (

).

4-

Press on PGM button to select Prog. 2 (

) and Hour and Min buttons to

 

enter 8:15 AM.

 

 

5- Repeat step 4 to enter Prog. 3 (5:00 PM) and Prog. 4 (10:00 PM).

NOTE : When making modifications, make sure you are in the right program.

To modify the Saturday and Sunday schedules:

6- Press on Day button until SA or SU is displayed.

7- Press on PGM button to select Prog. 1 (

) and Hour and Min

buttons to enter 7:30 AM.

 

8- Press on PGM button to select Prog. 2 (

) and then Clear button to

erase it.

 

9- Press on PGM button to select Prog. 3 (

) and then Clear button to

erase it.

 

10- Press on PGM button to select Prog. 4 (

) and then Hour and Min

buttons to enter 11:00 PM.

 

11- Press on Mode button to exit this function.

Temporary or permanent temperature bypass

This operation allows you to temporarily modify the floor temperature while you are in the Automatic mode. Simply press on orbuttons to select the desired temperature, or the or button to select the Comfort or Econo settings you have programmed.This temperature will be maintained until the beginning of the next programmed schedule.

You can also switch to the Vacation setting for a prolonged absence by pressing

on and at the same time.The display will show icon. In that case, the temperature bypass is permanent. To return to the normal operating mode, press on Mode button.

If you wish to immediately return to the programmed settings, press on Mode button twice.

CHARACTERISTICS

• Model:

TH111GFCI-P (120 VAC)

• Supply:

120 VAC, 50/60 Hz

• Load:

16.7 A maximum (resistive only)

• Power:

2000 watts (NI) @ 120 VAC

• Ground fault circuit interrupter (GFCI): 10 mA TRIP LEVEL

• Approvals:

CSA / C, US

• Display range:

0 to 60 °C (32 to 140 °F)

• Setting range:

5 to 40 °C (40 to 104 °F)

• Comfort default setting:

28 °C (82 °F)

• Econo default setting:

18 °C (64 °F)

• Storage:

-20 to 50 °C (-4 to 120 °F)

WARRANTY

AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY

This product is warranted against material defects and workmanship in normal use for a period of one year, from the date of the original purchase from author- ized dealers. During this period, AUBE technologies inc. will repair or replace the product with a new or of equivalent quality at AUBE'S option, without charge, any product proven defective in normal use.

Warranty does not cover transportation costs. Nor does it cover a product sub- jected to misuse or accidental damage. This warranty does not cover the cost of installation, removal or reinstallation.

This limited warranty is in lieu of all other warranties, obligations or liabilities expressed or implied by the company. In no event shall AUBE technologies inc. be liable for consequential or incidental damages resulting from installation of this product. Some states or provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential dam- ages, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

The defective product and the original sale receipt must be returned to the origi- nal dealer or shipped pre-paid, insured and addressed to:

Aube technologies inc., 705 Montrichard, Iberville (Quebec), Canada, J2X 5K8

www.aubetech.com

service@aubetech.com

If you have any questions concerning the installation or programming of this prod- uct, please call our technical assistance at (450) 358-4600 for the Montreal area or 1-800-831-AUBEfor outside area, Monday to Friday between 8:30 AM and 5:00 PM Eastern time.

09/05/02 920-111-021-00-1-A 2/2

Page 2
Image 2
Aube Technologies TH111GFCI-P manual Programming, Characteristics, Warranty