Aube Technologies TH113 A technical specifications TH1 1 3 & TH1 1 6 A/F/AF, Owner s Guide

Models: TH113 A TH113

1 2
Download 2 pages 26.45 Kb
Page 1
Image 1
TH1 1 3 & TH1 1 6 A/F/AF

TH1 1 3 & TH1 1 6 A/F/AF

Owner￿ s Guide

Model Selection (switch)

FOR A AND AF MODELS ONLY

Temperature Lock (TH1 1 3 only)

At the rear of the control module are two potentiometers.

Setpoint Definition

Turn the dial to the desired temperature.

Thank you for choosing Aube’s non- programmable thermostat. Your new electronic thermostat is equipped with a microprocessor and proportional integral adaptive (PIA) temperature control technology for total comfort. Depending on the selected model, this thermostat has been designed to control:

A: The Ambient temperature (using an electric heating system)

AF: The Ambient temperature with Floor temperature limit (using a floor heating system to heat the room)

F: The Floor temperature (floor heating)

NOTE: This control module must be mounted on a PB112 Series power base.

The thermostat has an On/Standby switch making it possible to put the thermostat in sleep mode when its use is no longer required (e.g. summer).

TH116

Public Area

TH113

At the rear of the control module is a switch that has been factory-set to the applicable temperature control.

NOTE: The AF model can be used for all temperature control types (A, F and AF).

Note: The ambient sensor is not operational when the switch is set to I (up).

These potentiometers act like a temperature lock. Even when occupants adjust the temperature using the dial on the front/rear of the control module, the potentiometers override the dial and maintain the temperature within the locked-in minimum and maximum range.

A - ambient temperature

￿F & AF - floor temperature limit

Use a flat tip screwdriver to rotate the potentiometers until the notch points to the desired temperature.

Potentiometers

Notch

TH113: The dial is located on the front of the control module.

TH116: The dial is located on the rear of the control module.

The min. position indicates the minimum temperature setpoint: 45°F (7°C).

Temperature

dial

TH113TH116

Control Module Installation

Align the bracket tabs on the control module with the holes located on the power base.

Follow the same procedure for the TH116.

Control module

Power base

NOTE: Keep the thermostat's air vents clean and free from obstructions.
NOTE: The screw cannot be removed completely.

GFCI Test

The GFCI monitors￿￿￿￿the￿￿￿￿￿electrical￿￿￿￿￿￿￿￿￿￿￿￿￿￿

flow for any loss of current; if

there is any loss, the thermostat will cut off power to the heating

system. We recommend you test

the GFCI immediately after installing the control module, and

once a month thereafter to ensure it is operating properly. To test:

!Press the TEST button:

Successful: TEST warn-

ing light is ON and power to heating system is cut off.

Unsucessful: The TEST warning light is OFF. Cut power to heating system from the main power panel and call customer service.

"When successful, reset thermostat (STANDBY/ON) to power heating system.

NOTE: If the test warning light comes ON during normal operation, cut power to heating system from the main power panel and have an electrician verify the installation.

Remote Input

The TH113 and TH116 are equipped with a remote input which allows connection of an optional telephone controller (CT240) or any other remote control system. When a command signal is received through this input, the thermostat automatically lowers its setpoint by 3.5°C. The LED lights up to indicate the signal’s presence (except for GA and GB models).

Bypass (not available for GA and GB power base):

The TEST button can be used to bypass the signal for a 2-hour period. The LED goes off to indicate the bypass.

NOTE: When combined with a GA/GB power base, the TEST button is used only for GFCI testing. The bypass function is not available with these power base models.

Technical Specifications

Models: TH113 and TH116 A / AF / F

Setting range: 45°F, 59°F to 95°F (7°C, 15°C to 35°C)

Potentiometers: minimum: 41°F to 77°F (5°C to 25°C) maximum: 59°F to 95°F (15°C to 35°C)

Accuracy: ± 0.9°F (0.5°C)

Storage: -4°F to 120°F (-20°C to 50°C)

Warranty

AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY

This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address:

Aube Technologies Inc.

705 Montrichard

Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8

If you have any questions concerning the TH113 or the TH116

thermostat, call our technical support team at:

Phone:

Montreal area: (450) 358-4600

Fax:

Canada / U.S.: 1-800-831-AUBE (2823)

y(450) 358-4650

Email:

service@aubetech.com

Monday to Friday from 8:30 AM to 5:00 PM EST. For more information on our products, visit us at:

www.aubetech.com

01/08/03 920-113-001-00-1-A