Error Code

Message Information

 

 

 

Details

The <name> battery is either missing, bad, or unable to

 

 

charge due to thermal issues.

 

Action

Check system fans. Replace the <name> battery.

BAT0019

Message

The <name> battery is absent.

 

 

LCD Message

The <name> battery is absent. Check battery.

 

Details

The failed or missing <name> battery may reduce system

 

 

performance.

 

Action

Check system fans. Replace the <name> battery.

CBL0006

Message

Multiple storage controllers are incorrectly connected to the

 

 

 

same backplane <Bay ID>.

 

Details

Unsupported backplane configuration.

 

Action

Check backplane configuration. Reconnect cable. If the issue

 

 

persists, see Getting Help.

CPU0000

Message

CPU <number> has an internal error (IERR).

 

 

LCD Message

CPU <number> has an internal error (IERR).

 

Details

System event log and OS logs may indicate that the

 

 

exception is external to the processor.

 

Action

Review System Event Log and Operating System Logs. If the

 

 

issue persists, see Getting Help.

CPU0001

Message

CPU <number> has a thermal trip (over-temperature) event.

 

 

LCD Message

CPU <number> has a thermal trip. Check CPU heat sink.

 

Details

The processor temperature increased beyond the

 

 

operational range.

 

Action

Review logs for fan failures, replace failed fans. If no fan

 

 

failures are detected, check inlet temperature (if available)

 

 

and reinstall processor heat-sink.

CPU0002

Message

CPU <number> has failed the built-in self-test (BIST).

 

 

Action

1.

Turn system off and remove input power for one

 

 

 

 

 

minute. Reapply input power and turn system on.

 

 

2.

Make sure the processor is seated correctly.

 

 

3.

If the issue persists, see Getting Help.

91

Page 91
Image 91
Dell M820 owner manual BAT0019 Message, CBL0006 Message, CPU0000 Message, CPU0001 Message, CPU0002 Message