Error Code

Message Information

 

 

Details

The memory may not be seated correctly, misconfigured, or

 

 

has failed. Memory size is reduced.

 

Action

Re-seat the memory modules. If the issue persists, see

 

 

Getting Help.

MEM0005

Message

Persistent correctable memory error limit reached for a

 

 

 

memory device at location(s) <location>.

 

LCD Message

Persistent correctable memory error limit reached for

 

 

<location>. Re-seat memory.

 

Details

The memory is operational. This an early indicator of a

 

 

possible future uncorrectable error.

 

Action

Re-seat the memory modules. If the issue persists, see

 

 

Getting Help.

MEM0007

Message

Unsupported memory configuration; check memory device

 

 

 

at location <location>.

 

LCD Message

Unsupported memory configuration. Check memory

 

 

<location>.

 

Details

The memory may not be seated correctly, misconfigured, or

 

 

has failed. Memory size is reduced.

 

Action

Check the memory configuration. Re-seat the memory

 

 

modules. If the issue persists, see Getting Help.

MEM0009

Message

Memory device at location <location> is throttled.

 

 

Details

System performance is degraded.

 

Action

If unexpected, review system logs for power or thermal

 

 

exceptions.

MEM0010

Message

Memory device at location <location> is over heating.

 

 

LCD Message

Memory device <location> is over heating. Check fans.

 

Details

System performance is degraded.

 

Action

If unexpected, review system logs for power or thermal

 

 

exceptions.

MEM0022

Message

Memory device at location <location> is absent.

 

 

Details

The memory may not be seated correctly, misconfigured, or

 

 

has failed. Memory size is reduced.

106

Page 106
Image 106
Dell M820 owner manual MEM0005 Message, MEM0007 Message, MEM0009 Message, MEM0010 Message, MEM0022 Message