Error Code

Message Information

 

 

Action

Check the network cable and network connections.

SEL1508

Message

Member <number> could not join the Chassis Group.

 

 

Details

The indicated member CMC is a leader of a different CMC

 

 

stacking group.

 

Action

Check if member CMC is a leader of a different chassis

 

 

group.

SEL1510

Message

An authentication error detected for Chassis Group Member

 

 

 

<number>.

 

Details

Group master CMC could not log into the group member

 

 

CMC.

 

Action

Check the login credentials of CMC.

SEL9900

Message

An unsupported event occurred.

 

 

Details

The current software version cannot decode this event. You

 

 

may need to review this event using a tool which displays

 

 

raw data such as Ipmitool with the -vvv option or Racadm

 

 

with the -E option.

 

Action

Upgrade the management software.

SWC4004

Message

A firmware or software incompatibility detected between

 

 

 

iDRAC in slot <number> and CMC.

 

Details

FlexAddress is not implemented in one of the versions of

 

 

firmware.

 

Action

Check the firmware versions of iDRAC and CMC. Update

 

 

with the latest version.

SWC4006

Message

A firmware or software incompatibility detected between

 

 

 

system BIOS in slot <number> and CMC.

 

Details

FlexAddress is not implemented in one of the versions of

 

 

firmware.

 

Action

Check the firmware versions of BIOS and CMC. Update with

 

 

the latest version.

SWC4008

Message

A firmware or software incompatibility detected between

 

CMC 1 and CMC 2.

136

Page 136
Image 136
Dell M820 owner manual SEL1508 Message, SEL1510 Message, SEL9900 Message, SWC4004 Message, SWC4006 Message, SWC4008 Message