Error Code Message Information
LCD Message PSU redundancy degraded. Check PSU cables.
Details The current power operational mode is non-redundant
because of a power supply exception, a power supply
inventory change, or a system power inventory change.
Action Check the event log for power supply failures. Review
system configuration and power consumption.
PWR1001 Message The system performance was degraded.
LCD Message System performance degraded. Check PSUs and system
configuration.
Details To avoid shutdown, system performance has been degraded.
Action Review system configuration and system logs for thermal or
environmental failures and warnings.
PWR1002 Message The system performance degraded because of thermal
protection.
Details To avoid shutdown, system performance has been degraded.
Action Review system configuration and system logs for thermal or
environmental failures and warnings.
PWR1003 Message The system performance degraded because cooling capacity
has changed.
Details The current power supply configuration does not meet the
platform requirements to enable redundancy. If a power
supply fails the system may shutdown.
Action If unintended, review system configuration and power
consumption and install power supplies accordingly. Check
power supply status for failures.
PWR1004 Message The system performance degraded because power capacity
has changed.
Details The system may power down or operate in a performance
degraded state.
Action Check the event log for power supply failures. Review
system configuration and power consumption and upgrade
or install power supplies accordingly.
PWR1005 Message The system performance degraded because the user-
defined power capacity has changed.
125