Error Code

Message Information

 

PCI2002

Message

A fatal IO error detected on a component at slot <number>.

 

 

LCD Message

Fatal IO error on slot <number>.

 

Details

System performance may be degraded, or system may fail to

 

 

operate.

 

Action

Cycle input power, update component drivers, remove and

 

 

reinstall the device.

PCI3000

Message

Device option ROM on embedded NIC failed to support Link

 

 

 

Tuning or FlexAddress.

 

Details

Either the BIOS, BMC/iDRAC, or LOM firmware is out of date

 

 

and does not support FlexAddress.

 

Action

Update BIOS, BMC/iDRAC, and LOM firmware. If the issue

 

 

persists, see Getting Help.

PCI3002

Message

Failed to program virtual MAC address on a component at

 

 

 

bus <bus>device<device>function <func>.

 

Details

Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of

 

 

date and does not support FlexAddress.

 

Action

Update BIOS, BMC/iDRAC, LOM, and mezzanine card

 

 

firmware. If the issue persists, see Getting Help.

PCI3004

Message

Device option ROM on mezzanine card <number> failed to

 

 

 

support Link Tuning or FlexAddress.

 

Details

Either the BIOS, BMC/iDRAC, or mezzanine card firmware is

 

 

out of date and does not support FlexAddress.

 

Action

Update BIOS, BMC/iDRAC, and mezzanine card firmware. If

 

 

the issue persists, see Getting Help.

PCI3006

Message

Failed to get Link Tuning or FlexAddress data from iDRAC.

 

 

Details

Either the BIOS or BMC/iDRAC firmware is out of date and

 

 

does not support FlexAddress.

 

Action

Update BIOS, and BMC/iDRAC firmware. If the issue persists,

 

 

see Getting Help.

PCI3008

Message

A non-fatal PCIe error detected on a component at bus

 

 

 

<bus>device<device>function <func>.

 

Details

System performance may be degraded.

115

Page 115
Image 115
Dell M820 owner manual PCI2002 Message, PCI3000 Message, PCI3002 Message, PCI3004 Message, PCI3006 Message, PCI3008 Message