Error Code

Message Information

 

 

 

LCD Message

Control panel temperature is outside of range.

 

Details

Ambient air temperature is too warm or one or more fans

 

 

may have failed.

 

Action

Check the system operating environment and review event

 

 

log for fan failures.

TMP0134

Message

The control panel temperature is outside of the allowable

 

 

 

range.

 

LCD Message

Control panel temperature is outside of range.

 

Details

Ambient air temperature is too warm or cool.

 

Action

Check the system operating environment and review event

 

 

log for fan failures.

VLT0100

Message

Processor module <name> voltage is less than the lower

 

 

 

warning threshold.

 

LCD Message

Processor module <name> voltage is outside of range.

 

Details

System hardware detected an over voltage or under voltage

 

 

condition.

 

 

If multiple voltage exceptions occur consecutively the

 

 

system may power down in fail-safe mode.

 

Action

1.

Review system logs for power supply exceptions.

 

 

 

 

2.

Remove the processor module. Inspect processor

 

 

 

socket for bent pins.

 

 

3.

If the issue persists, see Getting Help.

VLT0101

Message

Processor module <name> voltage is less than the lower

 

 

 

critical threshold.

 

LCD Message

Processor module <name> voltage is outside of range.

 

Details

System hardware detected an over voltage or under voltage

 

 

condition.

 

 

If multiple voltage exceptions occur consecutively the

 

 

system may power down in fail-safe mode.

 

Action

1.

Review system logs for power supply exceptions.

 

 

 

 

2.

Remove the processor module. Inspect processor

 

 

 

socket for bent pins.

 

 

3.

If the issue persists, see Getting Help.