Error Code

Message Information

 

 

 

 

4.

If the issue persists, see Getting Help.

CPU0203

Message

CPU <number> <name> voltage is greater than the upper

 

 

 

critical threshold.

 

LCD Message

CPU <number> <name> voltage is outside of range. Re-seat

 

 

CPU.

 

Details

High voltages may be the result of problem with the voltage

 

 

regulator or a problem with the processor. Elevated voltages

 

 

may result in damage to the processor or other system

 

 

electrical components. The system may power down.

 

Action

1.

Turn system off and remove input power for one

 

 

 

 

 

minute.

 

 

2.

Reapply input power and turn system on.

 

 

3.

Ensure the processor is seated correctly.

 

 

4.

If the issue persists, see Getting Help.

CPU0204

Message

CPU <number> <name> voltage is outside of range.

 

 

LCD Message

CPU <number> <name> voltage is outside of range. Re-seat

 

 

CPU.

 

Details

Voltages outside the allowable range may damage electrical

 

 

components or may cause the system to shutdown.

 

Action

1.

Turn system off and remove input power for one

 

 

 

 

 

minute.

 

 

2.

Ensure the processor is seated correctly.

 

 

3.

Reapply input power and turn system on.

 

 

4.

If the issue persists, see Getting Help.

CPU0700

Message

CPU <number> initialization error detected.

 

 

LCD Message

CPU <number> initialization error detected. Power cycle

 

 

system.

 

Details

System BIOS was unable to initialize the processor.

 

Action

1.

Turn system off and remove input power for one

 

 

 

 

 

minute.

 

 

2.

Ensure the processor is seated correctly.

 

 

3.

Reapply input power and turn system on.

95

Page 95
Image 95
Dell M820 owner manual CPU0203 Message, CPU0204 Message, CPU0700 Message