Error Code

Message Information

 

MEM1016

Message

Memory device at location <location> is not installed

 

 

 

correctly.

 

LCD Message

Memory <location> is not installed correctly. Reinstall.

 

Details

The memory may not be seated correctly, misconfigured, or

 

 

has failed. Memory size is reduced.

 

Action

Check the memory configuration. Re-seat the memory

 

 

modules. If the issue persists, see Getting Help.

MEM1205

Message

Memory mirror redundancy is lost. Check memory device at

 

 

 

location(s) <location>.

 

LCD Message

Memory mirror lost on <location>. Power cycle system.

 

Details

The memory may not be seated correctly, misconfigured, or

 

 

has failed.

 

Action

Check the memory configuration. Re-seat the memory

 

 

modules. If the issue persists, see Getting Help.

MEM1206

Message

Memory mirror redundancy is degraded. Check memory

 

 

 

device at location <location>.

 

Details

The memory may not be seated correctly, misconfigured, or

 

 

has failed.

 

Action

Check the memory configuration. Re-seat the memory

 

 

modules. If the issue persists, see Getting Help.

MEM1208

Message

Memory spare redundancy is lost. Check memory device at

 

 

 

location <location>.

 

LCD Message

Memory spare lost on <location>. Power cycle system.

 

Details

Memory sparing is no longer available.

 

Action

Re-seat the memory modules. If the issue persists, see

 

 

Getting Help.

MEM1212

Message

Memory redundancy is lost.

 

 

Details

The memory may not be seated correctly, misconfigured, or

 

 

has failed.

 

Action

Review system logs for memory exceptions. reinstall

 

 

memory at location <location>

MEM1214

Message

Memory redundancy is degraded.

 

108