Error Code | Message Information |
|
| LCD Message | The <name> temperature is outside of range. Check Fans |
| Action | Check the system operating environment and review event |
|
| log for fan failures. |
TMP0118 | Message | The system inlet temperature is less than the lower warning |
| ||
|
| threshold. |
| LCD Message | System inlet temperature is outside of range. |
| Details | Ambient air temperature is too cool. |
| Action | Check the system operating environment. |
TMP0119 | Message | The system inlet temperature is less than the lower critical |
| ||
|
| threshold. |
| LCD Message | System inlet temperature is outside of range. |
| Details | Ambient air temperature is too cool. |
| Action | Check the system operating environment. |
TMP0120 | Message | The system inlet temperature is greater than the upper |
| ||
|
| warning threshold. |
| LCD Message | System inlet temperature is outside of range. |
| Details | Ambient air temperature is too warm or one or more fans |
|
| may have failed. |
| Action | Check the system operating environment and review event |
|
| log for fan failures. |
TMP0121 | Message | The system inlet temperature is greater than the upper |
| ||
|
| critical threshold. |
| LCD Message | System inlet <name> temperature is outside of range. Check |
|
| Fans. |
| Details | Ambient air temperature is too warm or one or more fans |
|
| may have failed. |
| Action | Check the system operating environment and review event |
|
| log for fan failures. |
TMP0122 | Message | The system inlet temperature is outside of range. |
| ||
| LCD Message | System inlet <name> temperature is outside of range. Check |
|
| Fans. |
| Details | Ambient air temperature is too warm or cool. |
140