Error Code

Message Information

 

CPU0010

Message

CPU <number> is throttled.

 

 

Details

The CPU is throttled due to thermal or power conditions.

 

Action

Review system logs for power or thermal exceptions.

CPU0023

Message

CPU <number> is absent.

 

 

LCD Message

CPU <number> is absent. Check CPU.

 

Action

Verify processor installation. If present, re-seat the

 

 

processor.

CPU0100

Message

CPU <number> temperature is less than the lower warning

 

 

 

threshold.

 

Details

System performance may be degraded.

 

Action

Check system operating environment.

CPU0101

Message

CPU <number> temperature is less than the lower critical

 

 

 

threshold.

 

LCD Message

CPU <number> temperature is outside of range.

 

Details

System performance may be degraded.

 

Action

Check system operating environment, fans, and heat-sinks.

CPU0102

Message

CPU <number> temperature is greater than the upper

 

 

 

warning threshold.

 

Details

System performance may be degraded.

 

Action

Check system operating environment, fans, and heat-sinks.

CPU0103

Message

CPU <number> temperature is greater than the upper critical

 

 

 

threshold.

 

LCD Message

CPU <number> temperature is outside of range. Check fans.

 

Details

System performance may be degraded.

 

Action

Check system operating environment, fans, and heat-sinks.

CPU0104

Message

CPU <number> temperature is outside of range.

 

 

LCD Message

CPU <number> temperature is outside of range. Check fans.

 

Details

System performance may be degraded.

93

Page 93
Image 93
Dell M820 owner manual CPU0010 Message, CPU0023 Message, CPU0100 Message, CPU0101 Message, CPU0102 Message, CPU0103 Message